APU AUTO SHUT DOWN - NO ACCELERATION, Main Start Contactor Fault or Batteries not selected (APS 3200)


TASK 49-00-00-810-981-A
APU AUTO SHUT DOWN - NO ACCELERATION, Main Start Contactor Fault or Batteries not selected (APS 3200)


1. Possible Causes
  • the BAT 1 and 2 pushbutton switches are selected OFF
  • aircraft wiring
  • CONTACTOR-MAIN START [5KA]
  • P/BSW-APU/MASTER SW [14KD]
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
  • MOTOR-STARTER [8KA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
AMM 49-00-00-710-008
Operational Test of the APU
ASM 494201
AWM 494201
AMM 49-42-51-000-007
Removal of the Starter Motor (APS 3200)
AMM 49-42-51-400-007
Installation of the Starter Motor (APS 3200)
AMM 49-42-55-000-001
Removal of the Start Contactors
AMM 49-42-55-400-001
Installation of the Start Contactors
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-378-B ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
NOTE: Before you start the operational test of the APU, make sure that:
  • the battery charge limiters 1PB1 and 1PB2 are serviceable AMM 24-38-00-710-001 or AMM 24-38-00-710-001,
  • the BAT 1 and 2 pushbutton switches are pushed (the FAULT and OFF legends areoff). If the BAT 1 and 2 pushbutton switches are selected OFF , the start contactors are disconnected from the power supply,
  • the Ram Air Turbine is in the retracted position.
4. Fault Isolation
Subtask 49-00-00-810-343-C ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


ACFT BAT NOT SELECTED / CONTACTOR (5KA)
Fault Code Number: 051
Additionally:
Fault Code Number: 085


NOTE: The APU SHUTDOWNS report gives the maintenance message:
NO ACCELERATION - ACFT BAT NOT SELECTED / CONTACTOR (5KA)
APU Auto Shut Down Fault Code Number: 051


although the A/C batteries are selected ON:
  • do a check for continuity of the aircraft wiring from the ECB (59KD) AC/1 to the START CONTACTOR (5KA) B/3 ASM 494201. ESPM 2052210.
   (1) If there is no continuity:
   (2) If there is continuity:
  • do a check for a ground signal (with APU MASTER SW pushed) at the MAIN START CONTACTOR (5KA) B/5 ASM 494201.
     (a) If there is a ground signal:
       1 If the fault continues:
  • replace the P/BSW-APU/MASTER SW [14KD] .
       2 If the fault continues:
     (b) If there is no ground signal:
       1 If the fault continues:
       2 If the fault continues:
Subtask 49-00-00-710-379-B ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.