W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - OVERSPEED, ECB (59KD) Fault (APS 3200)


TASK 49-00-00-810-976-A
APU AUTO SHUT DOWN - OVERSPEED, ECB (59KD) Fault (APS 3200)


1. Possible Causes
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-366-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-335-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


ECB (59KD):
Fault Code Number: 068
Additionally:
Fault Code Number: 061


NOTE: The APU SHUTDOWNS report gives the maintenance message:
OVERSPEED - ECB 59KD
APU Auto Shut Down Fault Code Number: 068


Subtask 49-00-00-710-367-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:28 UTC