APU AUTO SHUT DOWN - SENSOR FAILURE, Cooling Fan/PMG assy fault (APS3200)


TASK 49-00-00-810-964-A
APU AUTO SHUT DOWN - SENSOR FAILURE, Cooling Fan/PMG assy fault (APS3200)


1. Possible Causes
  • aircraft wiring
  • Cooling Fan PMG Assy (8055KM)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-52-53-000-001
Removal of the PMG and Cooling Fan Assembly (APS 3200)
AMM 49-52-53-400-001
Installation of the PMG and Cooling Fan Assembly (APS 3200)
ASM 496100
3. Fault Confirmation
Subtask 49-00-00-710-342-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-323-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


COOLING FAN PMG ASSY (8055KM)
Fault Code Number: 114 or 144


NOTE: The APU SHUTDOWNS report gives the maintenance message:
SENSOR FAILURE - COOLING FAN PMG ASSY (8055KM)
APU Auto Shut Down Fault Code Number: 114 or 144


  • disconnect the connector P28 from the Cooling Fan PMG Assy (8055KM) and do a continuity check of the aircraft wiring between:
    Cooling Fan PMG Assy (8055KM) connector P28/1 and the ECB (59KD) connector 59KD-AB/H4 ASM 496100 ESPM 2052210 ESPM 2053210 ESPM 205321A.
   (1) If the fault continues:
Subtask 49-00-00-710-343-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.