APU Bleed Control Valve indication replaced by amber XX (APS 3200)


TASK 49-00-00-810-960-A
APU Bleed Control Valve indication replaced by amber XX (APS 3200)


1. Possible Causes
  • BLEED CONTROL VALVE (8051KM) (LVDT Fault)
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 49-00-00-810-942-A
Bleed Control Valve Fault (APS 3200)
AMM 31-32-00-860-001
Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-334-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
   (1) Do a check of the APU Bleed Control-Valve indication on the lower ECAM DU (APU Page).
   (2) On the MCDU, get access to the APU menu page SYSTEM REPORT/TEST AMM 31-32-00-860-001.
   (3) Select the LAST LEG REPORT page.
4. Fault Isolation
Subtask 49-00-00-810-319-B ** ON A/C NOT FOR ALL
A. Maintenance Action
   (1) If there is a CLASS 1 Fault Message

BLEED CTL VLV (8051KM)

and the Bleed Control Valve indication is replaced by amber XX:
   (2) If there is no CLASS 1 Fault Message and the Bleed Control Valve indication is replaced by amber XX:
Subtask 49-00-00-710-335-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:28 UTC