W DOC AIRBUS | TSM A320F

APU Generator electrical-parameter indication(s) replaced by amber XX (APS 3200)


TASK 49-00-00-810-959-A
APU Generator electrical-parameter indication(s) replaced by amber XX (APS 3200)


1. Possible Causes
  • connection between the EGIU-2 (22XU2) and the SDAC 1 and 2 (1WV1(2)) and/or the APU GCU (1XS)
  • [1XS]
  • [22XU2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-22-00-810-808-A
APU GEN Voltage, Frequency and Load Indication Lost or Incorrect
AMM 24-22-33-000-001
Removal of the EGIU-1(2)
AMM 24-22-33-400-002
Installation of the EGIU-1(2)
AMM 24-23-34-000-001
Removal of the GCU-APU
AMM 24-23-34-400-001
Installation of the GCU-APU
AMM 49-00-00-710-008
Operational Test of the APU
3. Fault Confirmation
Subtask 49-00-00-710-332-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
Do a check of the APU GEN electrical-parameter indications on the lower ECAM DU (APU Page).
4. Fault Isolation
Subtask 49-00-00-810-318-A ** ON A/C NOT FOR ALL
A. Maintenance Action
   (1) If all electrical parameter indications are replaced by amber XX:
  • do the trouble shooting of the connection between the EGIU-2 (22XU2) and the SDAC 1 and 2 (1WV1(2)) and/or the APU GCU (1XS) (Ref. TSM TASK 24-22-00-810-808).
   (2) If one or two electrical parameter indications are replaced by amber XX:
     (a) If the fault continues:
Subtask 49-00-00-710-333-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:28 UTC