APU Generator electrical-parameter indication(s) replaced by amber XX (APS 3200)
TASK 49-00-00-810-959-A
APU Generator electrical-parameter indication(s) replaced by amber XX (APS 3200)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-00-710-332-A ** ON A/C NOT FOR ALL
Subtask 49-00-00-810-318-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:28 UTC
APU Generator electrical-parameter indication(s) replaced by amber XX (APS 3200)
1. Possible Causes
connection between the EGIU-2 (22XU2) and the SDAC 1 and 2 (1WV1(2)) and/or the APU GCU (1XS) [1XS] [22XU2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-22-00-810-808-A | APU GEN Voltage, Frequency and Load Indication Lost or Incorrect |
| AMM 24-22-33-000-001 | Removal of the EGIU-1(2) |
| AMM 24-22-33-400-002 | Installation of the EGIU-1(2) |
| AMM 24-23-34-000-001 | Removal of the GCU-APU |
| AMM 24-23-34-400-001 | Installation of the GCU-APU |
| AMM 49-00-00-710-008 | Operational Test of the APU |
Subtask 49-00-00-710-332-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
Do a check of the APU GEN electrical-parameter indications on the lower ECAM DU (APU Page).
4. Fault IsolationDo a check of the APU GEN electrical-parameter indications on the lower ECAM DU (APU Page).
Subtask 49-00-00-810-318-A ** ON A/C NOT FOR ALL
A. Maintenance Action
(1) If all electrical parameter indications are replaced by amber XX:
Subtask 49-00-00-710-333-A ** ON A/C NOT FOR ALL (1) If all electrical parameter indications are replaced by amber XX:
- do the trouble shooting of the
connection between the EGIU-2 (22XU2) and the SDAC 1 and 2 (1WV1(2)) and/or the APU GCU (1XS) (Ref. TSM TASK 24-22-00-810-808).
- replace the
[1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
- replace the
[22XU2] AMM 24-22-33-000-001 and AMM 24-22-33-400-002.
B. Do the test given in Para. 3.