W DOC AIRBUS | TSM A320F

Continuous Load-Compressor Surge or Load-Compressor Reverse Flow (APS 3200)


TASK 49-00-00-810-947-A
Continuous Load-Compressor Surge or Load-Compressor Reverse Flow (APS 3200)


1. Possible Causes
  • COMPRESSOR DISCHARGE-PRESSURE SENSOR (8039KM)
  • BLD CTL VLV (8051KM)
  • INLET PRESSURE/TEMPERATURE SENSOR (8013KM)
  • wiring
  • INLET GUIDE-VANE ACTUATOR (8014KM)
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 49-00-00-810-937-A
No APU Bleed-Air Pressure, Low or Fluctuating APU Bleed-Air Pressure (with AIDS support) (APS 3200)
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-20-00-290-001
APU Power Plant Borescope Inspection (APS 3200)
AMM 49-23-17-000-001
Removal of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-23-17-400-001
Installation of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-23-51-000-003
Removal of the Inlet Guide Vane Actuator (APS 3200)
AMM 49-23-51-400-003
Installation of the Inlet Guide Vane Actuator (APS 3200)
AMM 49-51-19-000-002
Removal of the Sensor - Compressor Discharge Pressure (APS 3200)
AMM 49-51-19-400-002
Installation of the Sensor - Compressor Discharge Pressure (APS 3200)
AMM 49-51-53-000-001
Removal of the Bleed Control Valve (APS 3200)
AMM 49-51-53-400-001
Installation of the Bleed Control Valve (APS 3200)
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-320-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-307-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


BLD FLOW XDCR (8039KM) / BLD CTL VLV (8051KM)
Fault Code Number: 169


NOTE: Do a check and make sure that the orifices and the lines which are connected to the compressor discharge-pressure sensor are not clogged.
Clean the orifices and the lines if necessary.
Make sure that the Load Control Valve sense line is correctly installed and torqued.
NOTE: Do a check of the IGV Actuator guide pin for correct installation. If the pin is disengaged, replace the pin or carry out the APIC VSB 4500001-49-84.
   (1) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
         a If the fault continues:
         b If the fault continues:
       2 If the fault continues:
       3 If the fault continues:
  • do a check for air flow blockage by external parts or damaged plenum baffle of the air inlet.
       4 If the fault continues:
       5 If the fault continues:
Subtask 49-00-00-710-321-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:27 UTC