W DOC AIRBUS | TSM A320F

Low PMG Voltage (APS 3200)


TASK 49-00-00-810-931-A
Low PMG Voltage (APS 3200)


1. Possible Causes
  • wiring
  • COOLING FAN/PMG ASSY (8055KM)
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-52-53-000-001
Removal of the PMG and Cooling Fan Assembly (APS 3200)
AMM 49-52-53-400-001
Installation of the PMG and Cooling Fan Assembly (APS 3200)
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-298-B ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-238-C ** ON A/C NOT FOR ALL
A. If the APU SHUTDOWNS report gives the maintenance message:


COOLING FAN PMG ASSY (8055KM)
Fault Code Number: 002


   (1) If the fault continues:
  • do a test of the PMG fuse with a multimeter (diode scale):
    - place the positive lead on PIN 3 of P28 Connector and the negative lead on PIN 2.
    - if it is approx. 0.9V, the fuse is OK.
     (a) if the fuse is OK:
       1 If the fault continues:
     (b) if the fuse is blown:
Subtask 49-00-00-710-299-B ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:26 UTC