W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - NO ACCELERATION, Back-up Start Contactor Fault (APS 3200)


TASK 49-00-00-810-928-A
APU AUTO SHUT DOWN - NO ACCELERATION, Back-up Start Contactor Fault (APS 3200)


1. Possible Causes
  • wiring
  • CONTACTOR-BACK-UP START [10KA]
  • MOTOR-STARTER [8KA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
AMM 49-00-00-710-008
Operational Test of the APU
ASM 494201
AMM 49-42-51-000-007
Removal of the Starter Motor (APS 3200)
AMM 49-42-51-400-007
Installation of the Starter Motor (APS 3200)
AMM 49-42-55-000-001
Removal of the Start Contactors
AMM 49-42-55-400-001
Installation of the Start Contactors
3. Fault Confirmation
Subtask 49-00-00-710-293-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-231-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


CONTACTOR 10KA:
Fault Code Number: 051
Additionally:
Fault Code Number: 018 or 086


NOTE: The APU SHUTDOWNS report gives the maintenance message:
NO ACCELERATION - CONTACTOR 10KA
APU Auto Shut Down Fault Code Number: 051


   (1) If the fault continues:
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
Subtask 49-00-00-710-294-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:26 UTC