Emergency Shutdown on the Ground (APS 3200)
TASK 49-00-00-810-923-A
Emergency Shutdown on the Ground (APS 3200)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-00-710-288-A ** ON A/C NOT FOR ALL
Subtask 49-00-00-810-362-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:26 UTC
Emergency Shutdown on the Ground (APS 3200)
1. Possible Causes
- water ingress in panel 108VU
FIRE EMERG-STOP RELAY (5WF) - CTL SW-APU SHUT OFF [1KL]
- ENG/APU FIRE PNL [1WD]
- wiring
- ELECTRONIC CONTROL BOX [59KD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 05-23-10-200-003 | GENERAL VISUAL INSPECTION OF TAIL CONE APU AND ACCESSORY COMPARTMENT (EWIS) |
| ESPM 2052210 | |
| ESPM 2053210 | |
| AMM 26-22-00-710-001 | Operational Test of the APU Fire-Extinguishing Loop/Squib |
| AMM 26-22-00-710-002 | Operational Test of APU Auto-Fire-Exting. Circuit and the APU LP Fuel-Valve operation using each indiv. motor in turn and Test APU Emerg. Shutdown Circuit |
| AMM 49-00-00-710-005 | Self-Test of the ECB |
| AMM 49-11-11-000-003 | Removal of the Power Plant (APU) (APS 3200) |
| AMM 49-11-11-400-003 | Installation of the Power Plant (APU) (APS 3200) |
| AMM 49-61-34-000-002 | Removal of the Electronic Control Box (ECB) (APS 3200) |
| AMM 49-61-34-400-002 | Installation of the Electronic Control Box (ECB) (APS 3200) |
| AMM 49-62-00-710-004 | Operational Test of the Emergency Shutdown Circuit (using the APU Shut Off Switch 1KL) (APS 3200) |
| AMM 49-81-41-000-002 | Removal of the Exhaust Muffler (APS 3200) |
| AMM 49-81-41-400-002 | Installation of the Exhaust Muffler (APS 3200) |
Subtask 49-00-00-710-288-A ** ON A/C NOT FOR ALL
A. Do the subsequent checks.
(1) Make sure the APU FIRE pushbutton switch on the APU FIRE/WARN module (1WD) was not pushed by a person accidentally.
(2) Make sure the APU SHUT OFF (1KL) switch on the external power-control panel 108VU was not pushed by a person accidentally.
(3) Make sure that there is no water ingress in the external power-control panel 108VU.
(4) Make sure that the FDU is not triggered.
(5) Do the test of the APU fire detection system AMM 26-22-00-710-001.
(6) Do the test of the APU emergency shutdown system with the APU SHUT OFF pushbutton switch (1KL) AMM 49-62-00-710-004.
(7) Do the operational test of the APU AUTO Fire Extinguishing AMM 26-22-00-710-002.
(8) Do the ECB BITE Test AMM 49-00-00-710-005.
4. Fault Isolation(1) Make sure the APU FIRE pushbutton switch on the APU FIRE/WARN module (1WD) was not pushed by a person accidentally.
(2) Make sure the APU SHUT OFF (1KL) switch on the external power-control panel 108VU was not pushed by a person accidentally.
(3) Make sure that there is no water ingress in the external power-control panel 108VU.
(4) Make sure that the FDU is not triggered.
(5) Do the test of the APU fire detection system AMM 26-22-00-710-001.
(6) Do the test of the APU emergency shutdown system with the APU SHUT OFF pushbutton switch (1KL) AMM 49-62-00-710-004.
(7) Do the operational test of the APU AUTO Fire Extinguishing AMM 26-22-00-710-002.
(8) Do the ECB BITE Test AMM 49-00-00-710-005.
Subtask 49-00-00-810-362-A ** ON A/C NOT FOR ALL
A. If you find signs of water ingress in panel 108VU :
Subtask 49-00-00-810-213-A ** ON A/C NOT FOR ALL - remove the APU SHUT OFF switch (1KL).
- do a check for moisture/corrosion on the electrical connections.
- dry the electrical connections.
- re-install the APU SHUT OFF switch (1KL).
B. If you do not find the signs of a fire and the tests do not confirm the fault:
Subtask 49-00-00-810-214-A ** ON A/C NOT FOR ALL - do an inspection of the APU and the APU compartment and make sure that you do not find the signs of a fire AMM 05-23-10-200-003,
- do a check and make sure that the APU bleed-air duct is in the correct condition and connected correctly,
- do a check and make sure that the APU exhaust duct is in the correct condition and connected correctly.
- do the applicable repair(s).
- replace and/or connect the APU bleed-air duct correctly AMM 49-11-11-000-003 and AMM 49-11-11-400-003.
- replace and/or connect the APU exhaust muffler correctly AMM 49-81-41-000-002 and AMM 49-81-41-400-002.
- refer to Para. 4.B.
C. If the tests confirm the fault:
Subtask 49-00-00-810-215-B ** ON A/C NOT FOR ALL - do a check and make sure that the FIRE EMERG-STOP relay (5WF) is serviceable,
- do a check and make sure that the APU SHUT OFF pushbutton switch (1KL) is serviceable,
- do a check and make sure the APU FIRE/WARN module (1WD) is serviceable.
- replace the
FIRE EMERG-STOP RELAY (5WF) .
- replace the CTL SW-APU SHUT OFF [1KL] .
- replace the ENG/APU FIRE PNL [1WD] .
- do a check and repair the wiring :
- from the FIRE EMERG STOP relay (5WF) A/D1 to the ECB (59KD) AB/B4.
- from the APU FIRE/WARN module (1WD) F/S to the ECB (59KD) AB/B4.
- from the APU SHUT OFF pushbutton switch (1KL) 1 to the ECB (59KD) AB/B4 ESPM 2052210 ESPM 2053210.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-002 and AMM 49-61-34-400-002.
D. If the APU Last Leg Report gives the maintenance message:
Fault Code Number: 113, 136
(1) Replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-002 and AMM 49-61-34-400-002.
Subtask 49-00-00-810-216-A ** ON A/C NOT FOR ALL Fault Code Number: 113, 136
NOTE: The APU SHUTDOWNS report gives the maintenance message:
EMERGENCY STOP
APU Auto Shut Down Fault Code Number: 113, 136
EMERGENCY STOP
APU Auto Shut Down Fault Code Number: 113, 136
(1) Replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-002 and AMM 49-61-34-400-002.
E. If you do not find the signs of a fire and the tests give a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 49-00-00-810-217-A ** ON A/C NOT FOR ALL F. Do the tests as given in the Para. 3.