10V Pressure-Reference Fault (APS 3200)


TASK 49-00-00-810-906-A
10V Pressure-Reference Fault (APS 3200)


1. Possible Causes
  • ELECTRONIC CONTROL BOX [59KD]
  • wiring
  • INLET PRESSURE/TEMPERATURE SENSOR (8013KM)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-005
Self-Test of the ECB
AMM 49-23-17-000-001
Removal of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-23-17-400-001
Installation of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-51-19-000-002
Removal of the Sensor - Compressor Discharge Pressure (APS 3200)
AMM 49-51-19-400-002
Installation of the Sensor - Compressor Discharge Pressure (APS 3200)
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-260-A ** ON A/C NOT FOR ALL
A. Do the self test of the ECB AMM 49-00-00-710-005.
4. Fault Isolation
Subtask 49-00-00-810-157-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


ECB (59KD) / APU HARNESS (8001KM):
Fault Code Number: 123


   (1) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
         a If the fault continues:
Subtask 49-00-00-710-261-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.