W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - OVERTEMPERATURE, Inlet Guide Vane Actuator Fault (APS 3200)


TASK 49-00-00-810-905-A
APU AUTO SHUT DOWN - OVERTEMPERATURE, Inlet Guide Vane Actuator Fault (APS 3200)


1. Possible Causes
  • fuel leaks
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
  • INLET GUIDE-VANE ACTUATOR (8014KM)
  • FUEL CONTROL UNIT (8022KM)
  • FUEL FLOW DIVIDER (8024KM)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 28-22-00-810-801-A
APU Fuel System - Low Pressure
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 28-22-00-710-002
Operational Test of the APU Fuel-Pump System
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-23-51-000-003
Removal of the Inlet Guide Vane Actuator (APS 3200)
AMM 49-23-51-400-003
Installation of the Inlet Guide Vane Actuator (APS 3200)
AMM 49-23-51-710-001
Push/Pull Test of the Inlet Guide Vane Mechanism (APS 3200)
AMM 49-32-11-000-002
Removal of the Fuel Control Unit (APS 3200)
AMM 49-32-11-400-002
Installation of the Fuel Control Unit (APS 3200)
AMM 49-32-12-000-002
Removal of the Flow Divider (APS 3200)
AMM 49-32-12-400-002
Installation of the Flow Divider (APS 3200)
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-258-A ** ON A/C NOT FOR ALL
A. Check/Test
   (1) Do the operational test of the APU AMM 49-00-00-710-008.
NOTE: Make sure that the fuel supply to the APU is correct AMM 28-22-00-710-002. If the fuel supply is not correct, do the trouble shooting of APU low fuel pressure (Ref. TSM TASK 28-22-00-810-801).
NOTE: During the operational test of the APU, carefully examine the fuel lines from the fuel control unit to the inlet guide-vane actuator:
  • fuel leaks are not permitted, correct/replace as necessary.
4. Fault Isolation
Subtask 49-00-00-810-156-B ** ON A/C NOT FOR ALL
A. Maintenance Action
   (1) If the APU Last Leg Report gives the maintenance message:


IGV ACTR (8014KM)
Additionally:
  • If the APU Last Leg Report gives the maintenance message:
    ECB 59KD:
    Fault Code Number: 064 or 066


NOTE: The APU SHUTDOWNS report gives the maintenance message:
OVERTEMPERATURE - IGV ACTR (8014KM)
APU Auto Shut Down Fault Code Number: 098


     (a) If the fault continues:
   (2) If the APU Last Leg Report gives the maintenance message:


IGV ACTR (8014KM)
Fault Code Number: 098


NOTE: The APU SHUTDOWNS report gives the maintenance message:
OVERTEMPERATURE - IGV ACTR (8014KM)
APU Auto Shut Down Fault Code Number: 098


     (a) If the push/pull test is OK:
       1 If the fault continues:
         a If the fault continues:
         b If the fault continues:
Subtask 49-00-00-710-259-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:25 UTC