APU AUTO SHUT DOWN - OVERTEMPERATURE, Inlet Guide Vane Actuator Fault (APS 3200)
TASK 49-00-00-810-905-A
APU AUTO SHUT DOWN - OVERTEMPERATURE, Inlet Guide Vane Actuator Fault (APS 3200)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-00-710-258-A ** ON A/C NOT FOR ALL
Subtask 49-00-00-810-156-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:25 UTC
APU AUTO SHUT DOWN - OVERTEMPERATURE, Inlet Guide Vane Actuator Fault (APS 3200)
1. Possible Causes
- fuel leaks
- wiring
- ELECTRONIC CONTROL BOX [59KD]
INLET GUIDE-VANE ACTUATOR (8014KM) FUEL CONTROL UNIT (8022KM) FUEL FLOW DIVIDER (8024KM)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 28-22-00-810-801-A | APU Fuel System - Low Pressure |
| ESPM 2052210 | |
| ESPM 2053210 | |
| ESPM 205321A | |
| AMM 28-22-00-710-002 | Operational Test of the APU Fuel-Pump System |
| AMM 49-00-00-710-008 | Operational Test of the APU |
| AMM 49-23-51-000-003 | Removal of the Inlet Guide Vane Actuator (APS 3200) |
| AMM 49-23-51-400-003 | Installation of the Inlet Guide Vane Actuator (APS 3200) |
| AMM 49-23-51-710-001 | Push/Pull Test of the Inlet Guide Vane Mechanism (APS 3200) |
| AMM 49-32-11-000-002 | Removal of the Fuel Control Unit (APS 3200) |
| AMM 49-32-11-400-002 | Installation of the Fuel Control Unit (APS 3200) |
| AMM 49-32-12-000-002 | Removal of the Flow Divider (APS 3200) |
| AMM 49-32-12-400-002 | Installation of the Flow Divider (APS 3200) |
| ASM 496102 | |
| AMM 49-61-34-000-002 | Removal of the Electronic Control Box (ECB) (APS 3200) |
| AMM 49-61-34-400-002 | Installation of the Electronic Control Box (ECB) (APS 3200) |
Subtask 49-00-00-710-258-A ** ON A/C NOT FOR ALL
A. Check/Test
(1) Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation(1) Do the operational test of the APU AMM 49-00-00-710-008.
NOTE: Make sure that the fuel supply to the APU is correct AMM 28-22-00-710-002. If the fuel supply is not correct, do the trouble shooting of APU low fuel pressure (Ref. TSM TASK 28-22-00-810-801).
NOTE: During the operational test of the APU, carefully examine the fuel lines from the fuel control unit to the inlet guide-vane actuator:
- fuel leaks are not permitted, correct/replace as necessary.
Subtask 49-00-00-810-156-B ** ON A/C NOT FOR ALL
A. Maintenance Action
(1) If the APU Last Leg Report gives the maintenance message:
IGV ACTR (8014KM)
Additionally:
IGV ACTR (8014KM)
Fault Code Number: 098
Subtask 49-00-00-710-259-A ** ON A/C NOT FOR ALL (1) If the APU Last Leg Report gives the maintenance message:
IGV ACTR (8014KM)
Additionally:
- If the APU Last Leg Report gives the maintenance message:
ECB 59KD:
Fault Code Number: 064 or 066
NOTE: The APU SHUTDOWNS report gives the maintenance message:
OVERTEMPERATURE - IGV ACTR (8014KM)
APU Auto Shut Down Fault Code Number: 098
OVERTEMPERATURE - IGV ACTR (8014KM)
APU Auto Shut Down Fault Code Number: 098
- do a check and repair the wiring from the ECB (59KD) AB/G8, G9, E12, E11, E8, E9 to the INLET GUIDE-VANE ACTUATOR (8014KM) P21/1, 2, 3, 4, 5, 6 ASM 496102 ESPM 2052210 ESPM 2053210 ESPM 205321A.
- replace the ELECTRONIC CONTROL BOX [59KD] AMM 49-61-34-000-002 and AMM 49-61-34-400-002.
IGV ACTR (8014KM)
Fault Code Number: 098
NOTE: The APU SHUTDOWNS report gives the maintenance message:
OVERTEMPERATURE - IGV ACTR (8014KM)
APU Auto Shut Down Fault Code Number: 098
OVERTEMPERATURE - IGV ACTR (8014KM)
APU Auto Shut Down Fault Code Number: 098
- do the push/pull test of the IGV mechanism AMM 49-23-51-710-001.
- replace the
INLET GUIDE-VANE ACTUATOR (8014KM) AMM 49-23-51-000-003 and AMM 49-23-51-400-003.
- replace the
FUEL CONTROL UNIT (8022KM) AMM 49-32-11-000-002 and AMM 49-32-11-400-002.
- replace the
FUEL FLOW DIVIDER (8024KM) AMM 49-32-12-000-002 and AMM 49-32-12-400-002.
- do a check and repair the wiring from the ECB (59KD) AB/G8, G9, E12, E11, E8, E9 to the INLET GUIDE-VANE ACTUATOR (8014KM) P21/1, 2, 3, 4, 5, 6 ASM 496102 ESPM 2052210 ESPM 2053210 ESPM 205321A.
B. Do the test given in Para. 3.