W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - SURGE /REVERSE FLOW, Bleed Control Valve Fault (APS3200)


TASK 49-00-00-810-904-A
APU AUTO SHUT DOWN - SURGE /REVERSE FLOW, Bleed Control Valve Fault (APS3200)


1. Possible Causes
  • fuel leaks
  • INLET T-P SENSOR (8013KM)
  • BLEED CONTROL VALVE (8051KM)
  • wiring
  • ELECTRONIC CONTROL BOX [59KD]
  • BLD FLOW XDCR (8039KM)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 49-00-00-810-937-A
No APU Bleed-Air Pressure, Low or Fluctuating APU Bleed-Air Pressure (with AIDS support) (APS 3200)
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-20-00-290-001
APU Power Plant Borescope Inspection (APS 3200)
AMM 49-23-17-000-001
Removal of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-23-17-400-001
Installation of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-23-51-710-001
Push/Pull Test of the Inlet Guide Vane Mechanism (APS 3200)
AMM 49-51-19-000-002
Removal of the Sensor - Compressor Discharge Pressure (APS 3200)
AMM 49-51-19-400-002
Installation of the Sensor - Compressor Discharge Pressure (APS 3200)
AMM 49-51-53-000-001
Removal of the Bleed Control Valve (APS 3200)
AMM 49-51-53-400-001
Installation of the Bleed Control Valve (APS 3200)
ASM 496101
ASM 496102
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-256-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU (4005KM) AMM 49-00-00-710-008.
NOTE: During the operational test of the APU, carefully examine the fuel lines from the fuel control unit to the bleed control valve:
  • fuel leaks are not permitted, correct/replace as necessary.
4. Fault Isolation
Subtask 49-00-00-810-155-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


BLEED CTL VLV (8051KM):
Fault Code Number: 097
Additionally:
Fault Code Number: 096
or
Fault Code Number: 143
Additionally:
Fault Code Number: 169



NOTE: The APU SHUTDOWNS report gives the maintenance message:
SURGE / REVERSE FLOW - BLEED CTL VLV (8051KM)
APU Auto Shut Down Fault Code Number: 097 or 143


   (1) Do a check of the IGV Actuator guide pin for correct installation. If the pin is disengaged, replace the pin.
     (a) If the fault continues:
NOTE: If FCN 169 is related.
     (b) If the fault continues:
       1 If the fault continues:
. If the fault continues:
     (c) If the fault continues:
     (d) If the fault continues:
     (e) If the fault continues:
     (f) If the fault continues:
Subtask 49-00-00-710-257-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:40:36 UTC