W DOC AIRBUS | TSM A320F

Bleed Flow-Transducer Fault (APS 3200)


TASK 49-00-00-810-903-A
Bleed Flow-Transducer Fault (APS 3200)


1. Possible Causes
  • COMPRESSOR DISCHARGE-PRESSURE SENSOR (8039KM)
  • wiring
  • wiring
  • INLET T-P SENSOR (8013KM)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-23-17-000-001
Removal of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-23-17-400-001
Installation of the Inlet Pressure/Temperature Sensor (APS 3200)
AMM 49-51-19-000-002
Removal of the Sensor - Compressor Discharge Pressure (APS 3200)
AMM 49-51-19-400-002
Installation of the Sensor - Compressor Discharge Pressure (APS 3200)
ASM 496102
3. Fault Confirmation
Subtask 49-00-00-710-254-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-154-B ** ON A/C NOT FOR ALL
A. Maintenance Action
   (1) If the APU Last Leg Report gives the maintenance message:


BLD FLOW XDCR (8039KM):
Fault Code Number: 000 or 001


     (a) If the fault continues:
   (2) If the APU Last Leg Report gives the maintenance message:


BLD FLOW XDCR (8039KM):
Fault Code Number: 003 or 103 or 149


     (a) replace the COMPRESSOR DISCHARGE-PRESSURE SENSOR (8039KM) AMM 49-51-19-000-002 and AMM 49-51-19-400-002.
   (3) If the APU Last Leg Report gives the maintenance message:


BLD FLOW XDCR (8039KM):
Fault Code Number: 170


     (a) If the fault continues:
       1 If the fault continues:
         a If the fault continues:
   (4) If the APU Last Leg Report gives the maintenance message:


BLD FLOW XDCR (8039KM):
Fault Code Number: 171


     (a) do a check and repair the wiring between the Delta P Sensor (P24) and the ECB (59KD) ASM 496102 ESPM 2052210 ESPM 2053210 ESPM 205321A.
Subtask 49-00-00-710-255-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:24 UTC