APU AUTO SHUT DOWN - GEN HIGH OIL TEMP (APS 3200)
TASK 49-00-00-810-902-A
APU AUTO SHUT DOWN - GEN HIGH OIL TEMP (APS 3200)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-00-710-252-A ** ON A/C NOT FOR ALL
Subtask 49-00-00-810-153-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:24 UTC
APU AUTO SHUT DOWN - GEN HIGH OIL TEMP (APS 3200)
1. Possible Causes
- oil level in the APU oil reservoir is not sufficient
LUBE-PUMP OIL FILTER (8076KM) GENERATOR OIL FILTER (8069KM) - leaks on the oil system components or oil lines
- wiring
- GEN-APU [8XS]
- APU [4005KM]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2052210 | |
| ESPM 2053210 | |
| ESPM 205321A | |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 31-32-00-860-001 | Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page |
| AMM 49-00-00-710-008 | Operational Test of the APU |
| AMM 49-11-11-000-003 | Removal of the Power Plant (APU) (APS 3200) |
| AMM 49-11-11-400-003 | Installation of the Power Plant (APU) (APS 3200) |
| ASM 496102 | |
| AMM 49-90-00-600-004 | Check Oil Level and Replenish (APS 3200) |
| AMM 49-91-00-210-002 | Visual Inspection of the Lube Pump Filter and Generator-Scavenge Filter Differential-Pressure Indicator Position (APS 3200) |
Subtask 49-00-00-710-252-A ** ON A/C NOT FOR ALL
A. Do the subsequent checks and the operational test of the APU.
(1) Do a check and make sure that the cooling fan inlet duct, the oil cooler inlet duct and the oil cooler outlet duct are correctly attached and in the correct condition.
.push the APU MASTER SW p/bsw to ON,
.select the SYSTEM/REPORT TEST page APU AMM 31-32-00-860-001.
.select the APU DATA/OIL page.
LUBE-PUMP OIL FILTER (8076KM) and the GENERATOR OIL FILTER (8069KM) are serviceable AMM 49-91-00-210-002.
(4) Carefully examine the APU externally:
4. Fault Isolation(1) Do a check and make sure that the cooling fan inlet duct, the oil cooler inlet duct and the oil cooler outlet duct are correctly attached and in the correct condition.
- correct/replace as necessary.
.push the APU MASTER SW p/bsw to ON,
.select the SYSTEM/REPORT TEST page APU AMM 31-32-00-860-001.
.select the APU DATA/OIL page.
- if the oil level in the APU oil reservoir is not sufficient , do the oil servicing AMM 49-90-00-600-004.
(4) Carefully examine the APU externally:
- make sure that you do not find leaks on the oil system components or oil lines :
- correct/replace as necessary.
NOTE: Operate the APU for min. 10 minutes under full load. This makes sure that the oil temperature increases sufficiently.
Subtask 49-00-00-810-153-B ** ON A/C NOT FOR ALL
A. Maintenance Action
(1) If the APU Last Leg Report gives the maintenance message:
CHECK OIL SYSTEM / GENERATOR (8XS):
Fault Code Number: 047
Additionally:
Fault Code Number: 010 or 011
CHECK OIL SYSTEM / GENERATOR (8XS):
Fault Code Number: 047
Subtask 49-00-00-710-253-A ** ON A/C NOT FOR ALL (1) If the APU Last Leg Report gives the maintenance message:
CHECK OIL SYSTEM / GENERATOR (8XS):
Fault Code Number: 047
Additionally:
Fault Code Number: 010 or 011
NOTE: FCN 010, 011 on the Class 3 Faults Page
NOTE: The APU SHUTDOWNS report gives the maintenance message:
GEN HIGH OIL TEMP - CHECK OIL SYSTEM / GENERATOR 8XS
APU Auto Shut Down Fault Code Number: 047
GEN HIGH OIL TEMP - CHECK OIL SYSTEM / GENERATOR 8XS
APU Auto Shut Down Fault Code Number: 047
- do a check and repair the wiring between ECB (59KD) AB-C3,C4 and GEN-APU (8XS) P4,3 and 4 ASM 496102 ESPM 2052210 ESPM 2053210 ESPM 205321A.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- replace the APU [4005KM] AMM 49-11-11-000-003 and AMM 49-11-11-400-003.
CHECK OIL SYSTEM / GENERATOR (8XS):
Fault Code Number: 047
NOTE: The APU SHUTDOWNS report gives the maintenance message:
GEN HIGH OIL TEMP - CHECK OIL SYSTEM / GENERATOR 8XS
APU Auto Shut Down Fault Code Number: 047
GEN HIGH OIL TEMP - CHECK OIL SYSTEM / GENERATOR 8XS
APU Auto Shut Down Fault Code Number: 047
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- do a check and repair the wiring between ECB (59KD) AB/C3,C4 and GEN-APU (8XS) P4-3 and 4 ASM 496102 ESPM 2052210 ESPM 2053210 ESPM 205321A.
- replace the APU [4005KM] AMM 49-11-11-000-003 and AMM 49-11-11-400-003.
B. Do the test given in Para. 3.