W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - GEN HIGH OIL TEMP (APS 3200)


TASK 49-00-00-810-902-A
APU AUTO SHUT DOWN - GEN HIGH OIL TEMP (APS 3200)


1. Possible Causes
  • oil level in the APU oil reservoir is not sufficient
  • LUBE-PUMP OIL FILTER (8076KM)
  • GENERATOR OIL FILTER (8069KM)
  • leaks on the oil system components or oil lines
  • wiring
  • GEN-APU [8XS]
  • APU [4005KM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 24-23-51-000-001
Removal of the APU Generator
AMM 24-23-51-400-001
Installation of the APU Generator
AMM 31-32-00-860-001
Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-11-11-000-003
Removal of the Power Plant (APU) (APS 3200)
AMM 49-11-11-400-003
Installation of the Power Plant (APU) (APS 3200)
ASM 496102
AMM 49-90-00-600-004
Check Oil Level and Replenish (APS 3200)
AMM 49-91-00-210-002
Visual Inspection of the Lube Pump Filter and Generator-Scavenge Filter Differential-Pressure Indicator Position (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-252-A ** ON A/C NOT FOR ALL
A. Do the subsequent checks and the operational test of the APU.
   (1) Do a check and make sure that the cooling fan inlet duct, the oil cooler inlet duct and the oil cooler outlet duct are correctly attached and in the correct condition.
  • correct/replace as necessary.
   (2) Do a check of the oil level via the MCDU SYSTEM/REPORT TEST page APU:
.push the APU MASTER SW p/bsw to ON,
.select the SYSTEM/REPORT TEST page APU AMM 31-32-00-860-001.
.select the APU DATA/OIL page.
  • if the oil level in the APU oil reservoir is not sufficient , do the oil servicing AMM 49-90-00-600-004.
   (3) Do a check and make sure that the LUBE-PUMP OIL FILTER (8076KM) and the GENERATOR OIL FILTER (8069KM) are serviceable AMM 49-91-00-210-002.
   (4) Carefully examine the APU externally:
  • make sure that you do not find leaks on the oil system components or oil lines :
     (a) If you find external oil leaks:
  • correct/replace as necessary.
   (5) Do the operational test of the APU AMM 49-00-00-710-008.
NOTE: Operate the APU for min. 10 minutes under full load. This makes sure that the oil temperature increases sufficiently.
4. Fault Isolation
Subtask 49-00-00-810-153-B ** ON A/C NOT FOR ALL
A. Maintenance Action
   (1) If the APU Last Leg Report gives the maintenance message:


CHECK OIL SYSTEM / GENERATOR (8XS):
Fault Code Number: 047
Additionally:
Fault Code Number: 010 or 011

NOTE: FCN 010, 011 on the Class 3 Faults Page

NOTE: The APU SHUTDOWNS report gives the maintenance message:
GEN HIGH OIL TEMP - CHECK OIL SYSTEM / GENERATOR 8XS
APU Auto Shut Down Fault Code Number: 047


     (a) If the fault continues:
       1 If the fault continues:
   (2) If the APU Last Leg Report gives the maintenance message:


CHECK OIL SYSTEM / GENERATOR (8XS):
Fault Code Number: 047


NOTE: The APU SHUTDOWNS report gives the maintenance message:
GEN HIGH OIL TEMP - CHECK OIL SYSTEM / GENERATOR 8XS
APU Auto Shut Down Fault Code Number: 047


     (a) If the fault continues:
     (b) If the fault continues:
Subtask 49-00-00-710-253-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:24 UTC