W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - REVERSE FLOW, Bleed Ctl Valve and APU Bleed Check Valve Fault (APS 3200)


TASK 49-00-00-810-901-A
APU AUTO SHUT DOWN - REVERSE FLOW, Bleed Ctl Valve and APU Bleed Check Valve Fault (APS 3200)


1. Possible Causes
  • CHECK VALVE-APU BLEED [7260HM]
  • BLEED CONTROL VALVE (8051KM)
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 36-12-51-000-001
Removal of the Check Valve
AMM 36-12-51-400-001
Installation of the Check Valve
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-51-53-000-001
Removal of the Bleed Control Valve (APS 3200)
AMM 49-51-53-400-001
Installation of the Bleed Control Valve (APS 3200)
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-250-B ** ON A/C NOT FOR ALL
A. Do the subsequent checks and the operational test of the APU.
   (1) do a check for the quick disconnect pin of the IGV-ACTUATOR.
   (2) Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-152-B ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the operational test of the APU and the APU SHUTDOWNS report gives the maintenance message

REVERSE FLOW - BCV P33 AND BLEED CHECK VALVE 7260HM

   (1) If the fault continues:
   (2) If the fault continues:
Subtask 49-00-00-710-251-B ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:24 UTC