W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - HIGH OIL TEMPERATURE (APS 3200)


TASK 49-00-00-810-896-A
APU AUTO SHUT DOWN - HIGH OIL TEMPERATURE (APS 3200)


1. Possible Causes
  • oil level in the APU oil reservoir is not sufficient
  • air passages of the oil cooler are blocked
  • leaks on the oil system components or oil lines
  • OIL COOLER (8079KM)
  • wiring
  • LUBE-PUMP OIL FILTER (8076KM)
  • GENERATOR OIL FILTER (8069KM)
  • GEN-APU [8XS]
  • COOLING FAN ASSEMBLY (8055KM)
  • APU [4005KM]
  • SENSOR - TEMPERATURE, HIGH OIL [8084KM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 24-23-51-000-001
Removal of the APU Generator
AMM 24-23-51-400-001
Installation of the APU Generator
AMM 31-32-00-860-001
Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-11-11-000-003
Removal of the Power Plant (APU) (APS 3200)
AMM 49-11-11-400-003
Installation of the Power Plant (APU) (APS 3200)
AMM 49-52-53-000-001
Removal of the PMG and Cooling Fan Assembly (APS 3200)
AMM 49-52-53-400-001
Installation of the PMG and Cooling Fan Assembly (APS 3200)
ASM 496102
AMM 49-90-00-600-004
Check Oil Level and Replenish (APS 3200)
AMM 49-91-00-210-002
Visual Inspection of the Lube Pump Filter and Generator-Scavenge Filter Differential-Pressure Indicator Position (APS 3200)
AMM 49-91-44-000-003
Removal of the Oil Cooler (APS 3200)
AMM 49-91-44-100-002
Cleaning of the Oil Cooler (APS 3200)
AMM 49-91-44-400-003
Installation of the Oil Cooler (APS 3200)
AMM 49-91-51-000-002
Removal of the Oil-Sump Temperature Sensor (APS 3200)
AMM 49-91-51-400-002
Installation of the Oil-Sump Temperature Sensor (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-240-A ** ON A/C NOT FOR ALL
A. Do the subsequent checks and the operational test of the APU.
   (1) Do a check of the oil level via the MCDU SYSTEM/REPORT TEST page APU:
.push the APU MASTER SW p/bsw to ON,
.select the SYSTEM/REPORT TEST page APU AMM 31-32-00-860-001,
.select the APU DATA/OIL page.
  • if the oil level in the APU oil reservoir is not sufficient , do the oil servicing AMM 49-90-00-600-004.
   (2) Do a check and make sure that the cooling fan inlet duct, the oil cooler inlet duct and the oil cooler outlet duct are correctly attached and in the correct condition.
  • correct/replace as necessary.
   (3) Remove the oil-cooler inlet duct and do a check if the air passages of the oil cooler are blocked .
   (4) Carefully examine the APU externally:
  • make sure that you do not find leaks on the oil system components or oil lines :
     (a) If you find external oil leaks:
  • correct/replace as necessary.
   (5) Remove the cooling-fan inlet duct AMM 49-52-53-000-001 and turn the manual drive shaft of the cooling fan assy. Make sure that you can turn the manual drive shaft freely.
   (6) Do the operational test of the APU AMM 49-00-00-710-008.
NOTE: Operate the APU for 10 minutes minimum under full load. This makes sure that the oil temperature increases sufficiently.
4. Fault Isolation
Subtask 49-00-00-810-147-B ** ON A/C NOT FOR ALL
A. Maintenance Action
   (1) If the APU Last Leg Report gives the maintenance message:


CHECK OIL COOLER ASSY (8079KM):
Fault Code Number: 046


NOTE: The APU SHUTDOWNS report gives the maintenance message:
HIGH OIL TEMPERATURE - CHECK OIL COOLER ASSY (8079KM)
APU Auto Shut Down Fault Code Number: 046


     (a) If the fault continues:
  • do a check and make sure that the LUBE-PUMP OIL FILTER (8076KM) and the GENERATOR OIL FILTER (8069KM) are serviceable AMM 49-91-00-210-002.
       1 If the fault continues:
       2 If the fault continues:
         a If the fault continues:
   (2) If the APU Last Leg Report gives the maintenance message:


CHECK OIL COOLER ASSY (8079KM):
Fault Code Number: 046
Additionally:
Fault Code Number: 012 or 013

NOTE: FCN 012, 013 on the Class 3 Faults Page

NOTE: The APU SHUTDOWNS report gives the maintenance message:
HIGH OIL TEMPERATURE - CHECK OIL COOLER ASSY (8079KM)
APU Auto Shut Down Fault Code Number: 046


     (a) If the fault continues:
Subtask 49-00-00-710-241-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:24 UTC