W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - OVERSPEED, Fuel Control Unit or ECB Fault (APS 3200)


TASK 49-00-00-810-893-A
APU AUTO SHUT DOWN - OVERSPEED, Fuel Control Unit or ECB Fault (APS 3200)


1. Possible Causes
  • FUEL CONTROL UNIT (8022KM)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-32-11-000-002
Removal of the Fuel Control Unit (APS 3200)
AMM 49-32-11-400-002
Installation of the Fuel Control Unit (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-234-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-144-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


FUEL CTL UNIT (8022KM)
Fault Code Number: 068


NOTE: The APU SHUTDOWNS report gives the maintenance message:
OVERSPEED - FUEL CTL UNIT (8022KM)
APU Auto Shut Down Fault Code Number: 068


Subtask 49-00-00-710-235-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:40:36 UTC