W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - SENSOR FAILURE, Oil Sump and Generator-Oil Temperature Sensor Fault (APS 3200)


TASK 49-00-00-810-892-A
APU AUTO SHUT DOWN - SENSOR FAILURE, Oil Sump and Generator-Oil Temperature Sensor Fault (APS 3200)


1. Possible Causes
  • wiring
  • SENSOR - TEMPERATURE, HIGH OIL [8084KM]
  • GEN-APU [8XS]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 24-23-51-000-001
Removal of the APU Generator
AMM 24-23-51-400-001
Installation of the APU Generator
AMM 49-00-00-710-005
Self-Test of the ECB
ASM 496102
AMM 49-91-51-000-002
Removal of the Oil-Sump Temperature Sensor (APS 3200)
AMM 49-91-51-400-002
Installation of the Oil-Sump Temperature Sensor (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-232-A ** ON A/C NOT FOR ALL
A. Do the self-test of the ECB (59KD) AMM 49-00-00-710-005.
4. Fault Isolation
Subtask 49-00-00-810-143-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


OIL TEMP SNSR (8084KM) AND GENERATOR (8XS)
Fault Code Number: 122
Additionally:
Fault Code Number: 010 or 011 and 012 or 013
NOTE: FCN 010-013 on Class 3 Faults Page

NOTE: The APU SHUTDOWNS report gives the maintenance message:
SENSOR FAILURE - OIL TEMP SNSR 8084KM AND GENERATOR 8XS
APU Auto Shut Down Fault Code Number: 122
NOTE: Message does not appear in case of self-test of the ECB


   (1) If the fault continues:
     (a) If the fault continues:
Subtask 49-00-00-710-233-B ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:24 UTC