APU AUTO SHUT DOWN - SENSOR FAILURE, EGT Thermocouple 1 and ECB 59KD Fault (APS 3200)


TASK 49-00-00-810-890-A
APU AUTO SHUT DOWN - SENSOR FAILURE, EGT Thermocouple 1 and ECB 59KD Fault (APS 3200)


1. Possible Causes
  • EGT THERMOCOUPLE 1 (8057KM1)
  • ELECTRONIC CONTROL BOX [59KD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 49-70-00-810-813-A
EGT-Thermocouple 1 Defective (APS 3200)
AMM 49-00-00-710-008
Operational Test of the APU
AMM 49-61-34-000-002
Removal of the Electronic Control Box (ECB) (APS 3200)
AMM 49-61-34-400-002
Installation of the Electronic Control Box (ECB) (APS 3200)
AMM 49-72-15-000-001
Removal of the Thermocouple (APS 3200)
AMM 49-72-15-400-002
Installation of the Thermocouple (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-228-A ** ON A/C NOT FOR ALL
A. Do the operational test of the APU AMM 49-00-00-710-008.
4. Fault Isolation
Subtask 49-00-00-810-141-A ** ON A/C NOT FOR ALL
A. If an APU auto shutdown occurs during the operational test of the APU and the test gives the maintenance message:


EGT TC1 P30 AND ECB (59KD):


Subtask 49-00-00-710-229-A ** ON A/C NOT FOR ALL
B. Do the operational test of the APU AMM 49-00-00-710-008.
NOTE: After the subsequent flight, make sure that the fault does not continue.
   (1) If the APU CLASS 3 FAULTS page gives the maintenance message EGT TC1 P30 after the subsequent flight: