APU AUTO SHUT DOWN - SENSOR FAILURE, EGT Thermocouples Fault (APS 3200)
TASK 49-00-00-810-889-A
APU AUTO SHUT DOWN - SENSOR FAILURE, EGT Thermocouples Fault (APS 3200)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 49-00-00-710-226-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 49-00-00-810-140-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:24 UTC
APU AUTO SHUT DOWN - SENSOR FAILURE, EGT Thermocouples Fault (APS 3200)
1. Possible Causes
EGT THERMOCOUPLE 1 (8057KM1) EGT THERMOCOUPLE 2 (8057KM2) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2052210 | |
| ESPM 2053210 | |
| ESPM 205321A | |
| AMM 49-00-00-710-005 | Self-Test of the ECB |
| ASM 496102 | |
| AMM 49-72-15-000-001 | Removal of the Thermocouple (APS 3200) |
| AMM 49-72-15-400-002 | Installation of the Thermocouple (APS 3200) |
Subtask 49-00-00-710-226-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 49-00-00-810-140-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:
EGT TC1 (8057KM1) AND EGT TC2 (8057KM2):
Fault Code Number: 102
Additionally:
Fault Code Number: 035 or 036 and 037 or 038
Subtask 49-00-00-710-227-B ** ON A/C NOT FOR ALL EGT TC1 (8057KM1) AND EGT TC2 (8057KM2):
Fault Code Number: 102
Additionally:
Fault Code Number: 035 or 036 and 037 or 038
NOTE: FCN 035-038 on Class 3 Faults Page
NOTE: The APU SHUTDOWNS report gives the maintenance message:
SENSOR FAILURE - EGT TC1 (8057KM1) AND EGT TC2 (8057KM2)
APU Auto Shut Down Fault Code Number: 102
SENSOR FAILURE - EGT TC1 (8057KM1) AND EGT TC2 (8057KM2)
APU Auto Shut Down Fault Code Number: 102
NOTE: Message does not appear in case of self-test of the ECB
(1) If the fault continues:- replace the
EGT THERMOCOUPLE 1 (8057KM1) and theEGT THERMOCOUPLE 2 (8057KM2) AMM 49-72-15-000-001 and AMM 49-72-15-400-002.
- do a check and repair the wiring from the ECB (59KD) AB/A7, A6 to the EGT THERMOCOUPLE 1 (8057KM1) P30/1, 2 ASM 496102 ESPM 2052210 ESPM 2053210 ESPM 205321A.
- do a check and repair the wiring from the ECB (59KD) AB/A9, A8 to the EGT THERMOCOUPLE 2 (8057KM2) P31/1, 2 ASM 496102 ESPM 2052210 ESPM 2053210 ESPM 205321A.
B. Do the test given in Para. 3.