W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - SENSOR FAILURE, EGT Thermocouples Fault (APS 3200)


TASK 49-00-00-810-889-A
APU AUTO SHUT DOWN - SENSOR FAILURE, EGT Thermocouples Fault (APS 3200)


1. Possible Causes
  • EGT THERMOCOUPLE 1 (8057KM1)
  • EGT THERMOCOUPLE 2 (8057KM2)
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
ESPM 205321A
AMM 49-00-00-710-005
Self-Test of the ECB
ASM 496102
AMM 49-72-15-000-001
Removal of the Thermocouple (APS 3200)
AMM 49-72-15-400-002
Installation of the Thermocouple (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-226-A ** ON A/C NOT FOR ALL
A. Do the self-test of the ECB (59KD) AMM 49-00-00-710-005.
4. Fault Isolation
Subtask 49-00-00-810-140-B ** ON A/C NOT FOR ALL
A. If the APU Last Leg Report gives the maintenance message:


EGT TC1 (8057KM1) AND EGT TC2 (8057KM2):
Fault Code Number: 102
Additionally:
Fault Code Number: 035 or 036 and 037 or 038
NOTE: FCN 035-038 on Class 3 Faults Page

NOTE: The APU SHUTDOWNS report gives the maintenance message:
SENSOR FAILURE - EGT TC1 (8057KM1) AND EGT TC2 (8057KM2)
APU Auto Shut Down Fault Code Number: 102
NOTE: Message does not appear in case of self-test of the ECB


   (1) If the fault continues:
Subtask 49-00-00-710-227-B ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:24 UTC