W DOC AIRBUS | TSM A320F

APU AUTO SHUT DOWN - AIR-INTAKE NOT OPEN, Air-Intake Flap-Actuator Fault (APS 3200)


TASK 49-00-00-810-882-A
APU AUTO SHUT DOWN - AIR-INTAKE NOT OPEN, Air-Intake Flap-Actuator Fault (APS 3200)


1. Possible Causes
  • AIR INTAKE-FLAP ACTUATOR (4015KM)
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2052210
ESPM 2053210
AMM 49-16-00-710-004
Operational Test of the Air Intake Flap and Diverter (APS 3200)
ASM 491601
AMM 49-16-51-000-002
Removal of the Air-Intake Flap Actuator (APS 3200)
AMM 49-16-51-400-002
Installation of the Air-Intake Flap Actuator (APS 3200)
3. Fault Confirmation
Subtask 49-00-00-710-212-A ** ON A/C NOT FOR ALL
A. Do the operational test of the Air-Intake Flap Actuator (4015KM) AMM 49-16-00-710-004.
4. Fault Isolation
Subtask 49-00-00-810-133-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:


INLET FLAP ACTR (4015KM)
Fault Code Number: 121
Additionally:
Fault Code Number: 025 or 058 or None


NOTE: The APU SHUTDOWNS report gives the maintenance message:
AIR INTAKE NOT OPEN - INLET FLAP ACTR (4015KM)
APU Auto Shut Down Fault Code Number: 121


   (1) If the fault continues:
Subtask 49-00-00-710-213-A ** ON A/C NOT FOR ALL
B. Do the operational test of the Air-Intake Flap Actuator (4015KM) AMM 49-16-00-710-004.
[Rev.8 from Aug 2018] 2026.04.04 04:34:23 UTC