Failure of the ADIRU Detected by the IGGS
TASK 47-11-00-810-810-A
Failure of the ADIRU Detected by the IGGS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 47-11-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 47-11-00-810-059-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:23 UTC
Failure of the ADIRU Detected by the IGGS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-003 | SYSTEM TEST of the ADR |
| ASM 471101 | |
| AMM 47-31-34-000-001 | Removal of the IGGS Controller Unit |
| AMM 47-31-34-400-001 | Installation of the IGGS Controller Unit |
| AMM 47-31-34-740-001 | BITE Test of the IGGS with Bleed Air |
Subtask 47-11-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 47-11-00-810-059-A ** ON A/C NOT FOR ALL
A. Do the system test of the ADR AMM 34-13-00-740-003.
(1) If the test is not successful:
(4) If the fault continues
(a) do a check and repair the:
Subtask 47-11-00-710-051-A ** ON A/C NOT FOR ALL (1) If the test is not successful:
- replace the ADIRU-1 [1FP1] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- replace the IGGS CTL UNIT [1YA] AMM 47-31-34-000-001 and AMM 47-31-34-400-001
(4) If the fault continues
(a) do a check and repair the:
- wiring from ADIRU-1 [1FP1] pin TP/7A to IGGS CTL UNIT [1YA] pin A/112
- wiring from ADIRU-1 [1FP1] pin TP/7B to IGGS CTL UNIT [1YA] pin A/113 ASM 471101.
B. Do the test as given in the Para. 3.
NOTE: After the subsequent flight make sure that the fault does not continue.