Failure of the IGGS Control Unit 1YA detected by CSAS Control Unit 100HW
TASK 47-11-00-810-808-A
Failure of the IGGS Control Unit 1YA detected by CSAS Control Unit 100HW
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 47-11-00-740-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 47-11-00-810-057-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:23 UTC
Failure of the IGGS Control Unit 1YA detected by CSAS Control Unit 100HW
1. Possible Causes
- IGGS CTL UNIT [1YA]
- CSAS CONTROL UNIT [100HW]
wiring from IGGS CTL UNIT (1YA) pin A/115 to CSAS CTL UNIT (100HW) pin AB/H11 wiring from IGGS CTL UNIT (1YA) pin A/106 to CSAS CTL UNIT (100HW) pin AB/J11 wiring from IGGS CTL UNIT (1YA) pin A/86 to CSAS CTL UNIT (100HW) pin AB/H12 wiring from IGGS CTL UNIT (1YA) pin A/98 to CSAS CTL UNIT (100HW) pin AB/J12 wiring from IGGS CTL UNIT (1YA) pin A/2 to 103PP (28VDC NORM) wiring from IGGS CTL UNIT (1YA) pin A/3 to 103PP (28VDC NORM) wiring from IGGS CTL UNIT (1YA) pin A/4 to 103PP (28VDC NORM) wiring from IGGS CTL UNIT (1YA) pin A/5 to 103PP (28VDC NORM) - circuit breaker 7YA
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-58-34-000-001 | Removal of the CSAS Control Unit |
| AMM 21-58-34-400-001 | Installation of the CSAS Control Unit |
| ASM 471101 | |
| AMM 47-31-34-000-001 | Removal of the IGGS Controller Unit |
| AMM 47-31-34-400-001 | Installation of the IGGS Controller Unit |
| AMM 47-31-34-740-001 | BITE Test of the IGGS with Bleed Air |
Subtask 47-11-00-740-064-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 47-11-00-810-057-A ** ON A/C NOT FOR ALL
A. Procedure
(1) Replace the IGGS CTL UNIT [1YA] AMM 47-31-34-000-001 and AMM 47-31-34-400-001.
(2) Do the test given in para. 3.
(3) If the fault continues:
(a) Replace the CSAS CONTROL UNIT [100HW] AMM 21-58-34-000-001 and AMM 21-58-34-400-001.
(b) Do the BITE test of the IGGS without bleed air AMM 47-31-34-740-001.
(4) If the fault continues:
(a) Do a check and repair the:
Subtask 47-11-00-740-065-A ** ON A/C NOT FOR ALL (1) Replace the IGGS CTL UNIT [1YA] AMM 47-31-34-000-001 and AMM 47-31-34-400-001.
(2) Do the test given in para. 3.
(3) If the fault continues:
(a) Replace the CSAS CONTROL UNIT [100HW] AMM 21-58-34-000-001 and AMM 21-58-34-400-001.
(b) Do the BITE test of the IGGS without bleed air AMM 47-31-34-740-001.
(4) If the fault continues:
(a) Do a check and repair the:
wiring from IGGS CTL UNIT (1YA) pin A/115 to CSAS CTL UNIT (100HW) pin AB/H11 wiring from IGGS CTL UNIT (1YA) pin A/106 to CSAS CTL UNIT (100HW) pin AB/J11 wiring from IGGS CTL UNIT (1YA) pin A/86 to CSAS CTL UNIT (100HW) pin AB/H12 wiring from IGGS CTL UNIT (1YA) pin A/98 to CSAS CTL UNIT (100HW) pin AB/J12 wiring from IGGS CTL UNIT (1YA) pin A/2 to 103PP (28VDC NORM) wiring from IGGS CTL UNIT (1YA) pin A/3 to 103PP (28VDC NORM) wiring from IGGS CTL UNIT (1YA) pin A/4 to 103PP (28VDC NORM) wiring from IGGS CTL UNIT (1YA) pin A/5 to 103PP (28VDC NORM) ASM 471101.
B. Do the test given in para. 3.
NOTE: After the subsequent flight make sure that the fault does not continue.