W DOC AIRBUS | TSM A320F

Failure of the IGGS Pressure Sensor 5YA


TASK 47-11-00-810-805-A
Failure of the IGGS Pressure Sensor 5YA


1. Possible Causes
  • SENSOR-PRESS MONITORING, IGGS & ASM [5YA]
  • wiring from IGGS CTL UNIT (1YA) pin A/16 to IGGS PRESS SNSR (5YA) pin A/1
  • wiring from IGGS CTL UNIT (1YA) pin A/47 to IGGS PRESS SNSR (5YA) pin A/3
  • wiring from IGGS CTL UNIT (1YA) pin A/58 to IGGS PRESS SNSR (5YA) pin A/4
  • wiring from ground to IGGS PRESS SNSR (5YA) pin A/2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 471101
AMM 47-31-34-740-001
BITE Test of the IGGS with Bleed Air
AMM 47-41-13-000-001
Removal of the Pressure Sensor
AMM 47-41-13-400-001
Installation of the Pressure Sensor
3. Fault Confirmation
Subtask 47-11-00-740-058-A ** ON A/C NOT FOR ALL
A. Do the BITE test of the IGGS without bleed air AMM 47-31-34-740-001.
4. Fault Isolation
Subtask 47-11-00-810-054-A ** ON A/C NOT FOR ALL
A. Procedure
   (1) Replace the SENSOR-PRESS MONITORING, IGGS & ASM [5YA] AMM 47-41-13-000-001 and AMM 47-41-13-400-001.
   (2) Do the BITE test of the IGGS with bleed air AMM 47-31-34-740-001.
   (3) If the fault continues:
     (a) Do a check and repair the:
  • wiring from IGGS CTL UNIT (1YA) pin A/16 to IGGS PRESS SNSR (5YA) pin A/1
  • wiring from IGGS CTL UNIT (1YA) pin A/47 to IGGS PRESS SNSR (5YA) pin A/3
  • wiring from IGGS CTL UNIT (1YA) pin A/58 to IGGS PRESS SNSR (5YA) pin A/4
  • wiring from ground to IGGS PRESS SNSR (5YA) pin A/2 ASM 471101.
Subtask 47-11-00-740-059-A ** ON A/C NOT FOR ALL
B. Do the BITE test of the IGGS with bleed air AMM 47-31-34-740-001.
NOTE: After the subsequent flight make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:34:22 UTC