W DOC AIRBUS | TSM A320F

Loss of OOOI Data on the AOC FLT LOG Page on the MCDU


TASK 46-21-00-810-858-A
Loss of OOOI Data on the AOC FLT LOG Page on the MCDU


1. Possible Causes

2. Fault Confirmation
Subtask 46-21-00-740-159-A ** ON A/C NOT FOR ALL
A. Not applicable, the fault is evident.
3. Fault Isolation
Subtask 46-21-00-810-107-A ** ON A/C NOT FOR ALL
A. If the fault is identified by the crew observation:
OOOI data not available on AOC FLT LOG page on the MCDU.
   (1) OOOI data are computed from data given by a system which has an interface with the ATSU (for example, FWC). To know which data are used and the associated source, refer to your AOC supplier because AOC software components are customizable.
[Rev.8 from Aug 2018] 2026.04.04 04:34:22 UTC