W DOC AIRBUS | TSM A320F

Failure of the ATSU ISM Application


TASK 46-21-00-810-857-A
Failure of the ATSU ISM Application


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 46-21-00-610-001
Uploading of the ATSU Software with the PDL (SFIM or equivalent)
AMM 46-21-00-740-001
BITE Test of the ATIMS
3. Fault Confirmation
Subtask 46-21-00-740-156-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the ATIMS AMM 46-21-00-740-001.
4. Fault Isolation
Subtask 46-21-00-810-106-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
NOTE: There is no operational effect on the ATSU(1TX1) when the AOC AISM/ATSU1(1TX1) message is generated.
Re-installation of the ATSU ISM application will inhibit the AOC AISM/ATSU1(1TX1) message.
   (1) Do the uploading of the ATSU ISM application AMM 46-21-00-610-001:
  • ATSU ISM for the ATSU ISM APPLICATION software (31TX).
5. Close-up
Subtask 46-21-00-740-158-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:22 UTC