TASK 46-21-00-810-856-A
ATSU Software Uploading Not Possible
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 46-21-00-700-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 46-21-00-810-105-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:22 UTC
ATSU Software Uploading Not Possible
1. Possible Causes
wiring of the A/C on ground signal
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 46-21-00-610-001 | Uploading of the ATSU Software with the PDL (SFIM or equivalent) |
| ASM 462104 | |
| AMM 46-21-34-000-001 | Removal of the Air Traffic Service Unit (ATSU) |
| AMM 46-21-34-400-001 | Installation of the Air Traffic Service Unit (ATSU) |
Subtask 46-21-00-700-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 46-21-00-810-105-A ** ON A/C NOT FOR ALL
A. If WAIT RESPONSE stays in view on the MDDU:
(1) Remove the ATSU AMM 46-21-34-000-001.
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Do a check for a ground signal at pin AA/14G of the ATSU:
(a) If there is a ground signal:
1 Remove the LGCIU1 AMM 32-31-71-000-001.
2 Do a check and repair thewiring of the A/C on ground signal between:
4 Install the ATSU AMM 46-21-34-400-001.
Subtask 46-21-00-700-051-A ** ON A/C NOT FOR ALL (1) Remove the ATSU AMM 46-21-34-000-001.
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Do a check for a ground signal at pin AA/14G of the ATSU:
(a) If there is a ground signal:
- Install the ATSU AMM 46-21-34-400-001.
1 Remove the LGCIU1 AMM 32-31-71-000-001.
2 Do a check and repair the
- The pin AB/2H of the LGCIU1 and pin AA/14G of the ATSU
ASM 462104.
4 Install the ATSU AMM 46-21-34-400-001.
B. Do the test given in Para. 3.