ATSU Software Failure
TASK 46-21-00-810-847-A
ATSU Software Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 46-21-00-740-140-A 4. Fault Isolation
Subtask 46-21-00-810-097-A
Subtask 46-21-00-740-141-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:21 UTC
ATSU Software Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 46-21-00-740-001 | BITE Test of the ATIMS |
Subtask 46-21-00-740-140-A 4. Fault Isolation
Subtask 46-21-00-810-097-A
A. If the test gives the maintenance message ATSU1(1TX1) or if the fault symptom identified by the crew observation is "Access to ATSU menu not possible on the MCDU MENU page":
(1) Open and close the circuit breakers 3TX1 and 5TX1 to reset the ATSU (wait one minute approximately).
5. Close-up(1) Open and close the circuit breakers 3TX1 and 5TX1 to reset the ATSU (wait one minute approximately).
Subtask 46-21-00-740-141-A
A. Do the test given in Para. 3.