Loss of the HFDR2 Data Detected by the ATSU
TASK 46-21-00-810-846-A
Loss of the HFDR2 Data Detected by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 46-21-00-865-053-A
Subtask 46-21-00-810-096-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:21 UTC
Loss of the HFDR2 Data Detected by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-11-33-000-001 | Removal of the HF Transceiver |
| AMM 23-11-33-400-001 | Installation of the HF Transceiver |
| AMM 46-21-00-740-001 | BITE Test of the ATIMS |
| ASM 462105 | |
| AMM 46-21-34-000-001 | Removal of the Air Traffic Service Unit (ATSU) |
| AMM 46-21-34-400-001 | Installation of the Air Traffic Service Unit (ATSU) |
Subtask 46-21-00-865-053-A
A. Table of the circuit breakers used in this procedure:
Subtask 46-21-00-740-138-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | ATSU 1 | 3TX1 | L16 |
| 121VU | ATSU 1/SWTG | 5TX1 | L15 |
Subtask 46-21-00-810-096-A
A. If the test gives the maintenance message HFDR2(3RE2)/ATSU1(1TX1):
(1) Make sure that the circuit breakers 1RE2, 3TX1 and 5TX1 are closed.
(a) If the fault continues:
Subtask 46-21-00-740-139-A (1) Make sure that the circuit breakers 1RE2, 3TX1 and 5TX1 are closed.
(a) If the fault continues:
- open and close the circuit breaker 1RE2 to reset the HFDR2.
- open and close the circuit breakers 3TX1 and 5TX1 to reset the ATSU.
- replace the
[3RE2] AMM 23-11-33-000-001 and AMM 23-11-33-400-001.
- replace the ATSU [1TX1] AMM 46-21-34-000-001 and AMM 46-21-34-400-001.
- remove the HFDR2 and the ATSU
- do a check and repair the wiring of the HF2 OUTPUT BUS : between pins AA/9C,9D of the HFDR2 and pins AA/4E,4F of the ATSU ASM 462105
- install the HFDR2 and the ATSU.
B. Do the test given in Para. 3.