W DOC AIRBUS | TSM A320F

Loss of the HFDR2 Data Detected by the ATSU


TASK 46-21-00-810-846-A
Loss of the HFDR2 Data Detected by the ATSU


1. Possible Causes
  • [3RE2]
  • ATSU [1TX1]
  • wiring of the HF2 OUTPUT BUS
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-11-33-000-001
Removal of the HF Transceiver
AMM 23-11-33-400-001
Installation of the HF Transceiver
AMM 46-21-00-740-001
BITE Test of the ATIMS
ASM 462105
AMM 46-21-34-000-001
Removal of the Air Traffic Service Unit (ATSU)
AMM 46-21-34-400-001
Installation of the Air Traffic Service Unit (ATSU)
3. Fault Confirmation
Subtask 46-21-00-865-053-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUATSU 13TX1L16
121VUATSU 1/SWTG5TX1L15
Subtask 46-21-00-740-138-A
B. Test
   (1) Do the BITE test of the ATIMS AMM 46-21-00-740-001.
4. Fault Isolation
Subtask 46-21-00-810-096-A
A. If the test gives the maintenance message HFDR2(3RE2)/ATSU1(1TX1):
   (1) Make sure that the circuit breakers 1RE2, 3TX1 and 5TX1 are closed.
     (a) If the fault continues:
  • open and close the circuit breaker 1RE2 to reset the HFDR2.
       1 If the fault continues:
  • open and close the circuit breakers 3TX1 and 5TX1 to reset the ATSU.
   (2) If the fault continues:
     (a) If the fault continues:
       1 If the fault continues:
  • remove the HFDR2 and the ATSU
  • do a check and repair the wiring of the HF2 OUTPUT BUS : between pins AA/9C,9D of the HFDR2 and pins AA/4E,4F of the ATSU ASM 462105
  • install the HFDR2 and the ATSU.
Subtask 46-21-00-740-139-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:21 UTC