W DOC AIRBUS | TSM A320F

No VOICE mode set through the RMPs


TASK 46-21-00-810-842-A
No VOICE mode set through the RMPs


1. Possible Causes
  • RMP-COM/NAV FREQ SEL, 1 [1RG1]
  • RMP-COM/NAV FREQ SEL, 2 [1RG2]
  • [1RG3]
  • wiring of the VOICE/DATA SELECT OUTPUT
  • wiring of the VOICE/DATA MONITOR INPUT
  • ATSU [1TX1]
  • wiring of the REMOTE VOICE/DATA SELECT
  • wiring of the PORT SELECT DISCRETE
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
AMM 46-21-00-710-001
Operational Test of the ATSU
ASM 462105
AMM 46-21-34-000-001
Removal of the Air Traffic Service Unit (ATSU)
AMM 46-21-34-400-001
Installation of the Air Traffic Service Unit (ATSU)
3. Fault Confirmation
Subtask 46-21-00-740-130-A
A. Test
   (1) Do the operational test of the ATSU AMM 46-21-00-710-001 from the step 35.
Do it again for each RMP.
4. Fault Isolation
Subtask 46-21-00-810-092-A
A. If you cannot select the VOICE mode from one RMP, do the fault isolation procedure that follows:
   (1) If you can correctly set the VOICE mode on the two other RMPs
     (a) Replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] , RMP-COM/NAV FREQ SEL, 2 [1RG2] or [1RG3] on which it was not possible to set the VOICE mode AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
     (b) If the fault continues:
  • remove the same RMP
  • do a check and repair if necessary the wiring of the VOICE/DATA SELECT OUTPUT from the pin A/G of the RMP to the RMP derivation terminal block ASM 462105
     (c) If the fault continues:
  • do a check and repair if necessary the wiring of the VOICE/DATA MONITOR INPUT from the RMP derivation terminal block to pin A/F of the RMP ASM 462105
  • install the RMP that you removed.
   (2) If you cannot set the VOICE mode on the two other RMPs:
     (a) Remove the ATSU [1TX1] AMM 46-21-34-000-001
  • do a check and repair if necessary the wiring of the REMOTE VOICE/DATA SELECT from pin AA/15A of the ATSU to the RMP derivation terminal block ASM 462105
     (b) If the fault continues:
  • do a check and repair if necessary the wiring of the PORT SELECT DISCRETE from AA/12B of the ATSU to the RMP derivation terminal block ASM 462105.
     (c) If the fault stops:
     (d) If the fault continues:
Subtask 46-21-00-740-131-A
B. Do the test given in Para. 3.A.