Loss of the DMU Data Detected by the ATSU
TASK 46-21-00-810-823-A
Loss of the DMU Data Detected by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 46-21-00-740-092-A 4. Fault Isolation
Subtask 46-21-00-810-071-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:19 UTC
Loss of the DMU Data Detected by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-36-34-000-001 | Removal of the Data Management Unit (DMU) |
| AMM 31-36-34-400-001 | Installation of the Data Management Unit (DMU) |
| AMM 46-21-00-740-001 | BITE Test of the ATIMS |
| ASM 462105 | |
| AMM 46-21-34-000-001 | Removal of the Air Traffic Service Unit (ATSU) |
| AMM 46-21-34-400-001 | Installation of the Air Traffic Service Unit (ATSU) |
Subtask 46-21-00-740-092-A 4. Fault Isolation
Subtask 46-21-00-810-071-A
A. If the test gives the maintenance message DMU(1TV)/ATSU1(1TX1):
Subtask 46-21-00-740-093-A - replace the DMU [1TV] AMM 31-36-34-000-001 and AMM 31-36-34-400-001.
- replace the ATSU [1TX1] AMM 46-21-34-000-001 and AMM 46-21-34-400-001.
- remove the DMU and the ATSU
- do a check and repair the wiring of the AIDS DATA BUS : between pins AB/11J,11K of the DMU and pins AB/8A,8B of the ATSU ASM 462105
- install the DMU and the ATSU.
B. Do the test given in Para. 3.