Loss of the DIU data by the ATSU
TASK 46-21-00-810-819-A
Loss of the DIU data by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 46-21-00-740-084-A 4. Fault Isolation
Subtask 46-21-00-810-067-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:19 UTC
Loss of the DIU data by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-34-34-000-001 | Removal of the Digital Interface Unit (DIU) |
| AMM 23-34-34-400-001 | Installation of the Digital Interface Unit (DIU) |
| AMM 46-21-00-740-001 | BITE Test of the ATIMS |
| ASM 462105 | |
| AMM 46-21-34-000-001 | Removal of the Air Traffic Service Unit (ATSU) |
| AMM 46-21-34-400-001 | Installation of the Air Traffic Service Unit (ATSU) |
Subtask 46-21-00-740-084-A 4. Fault Isolation
Subtask 46-21-00-810-067-A
A. If the test gives the maintenance message CT2(190MH)/ATSU1(1TX1):
Subtask 46-21-00-740-085-A - replace the
[190MH] AMM 23-34-34-000-001 and AMM 23-34-34-400-001.
- replace the ATSU [1TX1] AMM 46-21-34-000-001 and AMM 46-21-34-400-001.
- remove the DIU and the ATSU
- do a check and repair the wiring of the Cabin Terminal 2 DATA BUS : between the ATSU and the DIU ASM 462105.
- install the DIU and the ATSU.
B. Do the test given in Para. 3.