W DOC AIRBUS | TSM A320F

Loss of the CPMU data by the ATSU


TASK 46-21-00-810-818-A
Loss of the CPMU data by the ATSU


1. Possible Causes
  • [2RF]
  • ATSU [1TX1]
  • wiring of the Cabin Terminal 1 DATA BUS
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-74-31-000-001
Removal of the Cabin Management Terminal
AMM 23-74-31-400-001
Installation of the Cabin Management Terminal
AMM 46-21-00-740-001
BITE Test of the ATIMS
ASM 462105
AMM 46-21-34-000-001
Removal of the Air Traffic Service Unit (ATSU)
AMM 46-21-34-400-001
Installation of the Air Traffic Service Unit (ATSU)
3. Fault Confirmation
Subtask 46-21-00-740-082-A
A. Test
   (1) Do the BITE test of the ATIMS AMM 46-21-00-740-001.
4. Fault Isolation
Subtask 46-21-00-810-066-A
A. If the test gives the maintenance message CT1(2RF)/ATSU1(1TX1):
   (1) If the fault continues:
     (a) If the fault continues:
  • remove the Cabin Management Interface Unit and the ATSU
  • do a check and repair the wiring of the Cabin Terminal 1 DATA BUS : between the ATSU and the Cabin Management Interface Unit ASM 462105.
  • install the Cabin Management Interface Unit and the ATSU
Subtask 46-21-00-740-083-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:19 UTC