Loss of the CPMU data by the ATSU
TASK 46-21-00-810-818-A
Loss of the CPMU data by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 46-21-00-740-082-A 4. Fault Isolation
Subtask 46-21-00-810-066-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:19 UTC
Loss of the CPMU data by the ATSU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-74-31-000-001 | Removal of the Cabin Management Terminal |
| AMM 23-74-31-400-001 | Installation of the Cabin Management Terminal |
| AMM 46-21-00-740-001 | BITE Test of the ATIMS |
| ASM 462105 | |
| AMM 46-21-34-000-001 | Removal of the Air Traffic Service Unit (ATSU) |
| AMM 46-21-34-400-001 | Installation of the Air Traffic Service Unit (ATSU) |
Subtask 46-21-00-740-082-A 4. Fault Isolation
Subtask 46-21-00-810-066-A
A. If the test gives the maintenance message CT1(2RF)/ATSU1(1TX1):
Subtask 46-21-00-740-083-A - replace the
[2RF] AMM 23-74-31-000-001 and AMM 23-74-31-400-001.
- replace the ATSU [1TX1] AMM 46-21-34-000-001 and AMM 46-21-34-400-001.
- remove the Cabin Management Interface Unit and the ATSU
- do a check and repair the wiring of the Cabin Terminal 1 DATA BUS : between the ATSU and the Cabin Management Interface Unit ASM 462105.
- install the Cabin Management Interface Unit and the ATSU
B. Do the test given in Para. 3.