W DOC AIRBUS | TSM A320F

Loss of the FMGC2 FM ACARS Input Signal


TASK 46-21-00-810-808-A
Loss of the FMGC2 FM ACARS Input Signal


1. Possible Causes
  • FMGC-2 [1CA2]
  • ATSU [1TX1]
  • wiring of the PRINTER ACARS & ATSU DATA BUS
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
AMM 46-21-00-740-001
BITE Test of the ATIMS
ASM 462105
AMM 46-21-34-000-001
Removal of the Air Traffic Service Unit (ATSU)
AMM 46-21-34-400-001
Installation of the Air Traffic Service Unit (ATSU)
3. Fault Confirmation
Subtask 46-21-00-740-064-A
A. Test
   (1) Do the BITE test of the ATIMS AMM 46-21-00-740-001.
4. Fault Isolation
Subtask 46-21-00-810-057-A
A. If the test gives the maintenance message :
FMGC2(1CA2) BUS FM ACARS/ATSU1(1TX1):
   (1) If the fault continues:
     (a) If the fault continues:
  • remove the FMGC 2 and the ATSU
  • do a check and repair the wiring of the PRINTER ACARS & ATSU DATA BUS: between pins AB/12F,12G of the FMGC 2 and pins AB/7C,7D of the ATSU ASM 462105
  • install the FMGC 2 and the ATSU.
Subtask 46-21-00-740-065-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:34:18 UTC