W DOC AIRBUS | TSM A320F

Failure of the AOC Application


TASK 46-21-00-810-802-A
Failure of the AOC Application


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 46-21-00-610-001
Uploading of the ATSU Software with the PDL (SFIM or equivalent)
AMM 46-21-00-740-001
BITE Test of the ATIMS
AMM 46-21-34-000-001
Removal of the Air Traffic Service Unit (ATSU)
AMM 46-21-34-400-001
Installation of the Air Traffic Service Unit (ATSU)
3. Fault Confirmation
Subtask 46-21-00-740-054-A
A. Test
   (1) Do the BITE test of the ATIMS AMM 46-21-00-740-001.
4. Fault Isolation
Subtask 46-21-00-810-052-A
A. If the test gives the maintenance message AOC RAOC/ATSU1(1TX1) or if the AOC prompt is not shown on the ATSU DATALINK page on the MCDU:
  • load an AOC database with a Part Number that is different to the one applicable to this aircraft AMM 46-21-00-610-001.
  • start the ATSU again
  • then load the AOC database with the Part Number applicable to this aircraft.
   (1) If the fault continues:
Subtask 46-21-00-740-055-A
B. Do the test given in Para. 3.