W DOC AIRBUS | TSM A320F

Unsatisfactory Air Pressure in the Air Supply System


TASK 38-42-00-810-802-A
Unsatisfactory Air Pressure in the Air Supply System


1. Possible Causes
  • SWITCH,PRESSURE [10MD]
  • VALVE-PRESSURE REDUCING [4200MM]
  • COMPRESSOR [8MD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-41-00-820-001
Adjustment of the Pressure Reducing and Relief Valve
AMM 38-41-43-000-001
Removal of the Pressure Reducing Valve
AMM 38-41-43-400-001
Installation of the Pressure Reducing Valve
AMM 38-42-00-710-001
Operational Test of the Auxiliary Air Supply System.
AMM 38-42-00-720-001
Functional Test of the Pressure Switch
AMM 38-42-16-000-001
Removal of the Pressure Switch
AMM 38-42-16-400-001
Installation of the Pressure Switch
AMM 38-42-51-000-001
Removal of the Compressor
AMM 38-42-51-400-001
Installation of the Compressor
3. Fault Confirmation
Subtask 38-42-00-710-054-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do a test of the auxiliary air-supply system AMM 38-42-00-710-001.
4. Fault Isolation
Subtask 38-42-00-810-053-A ** ON A/C NOT FOR ALL
A. If the test is not satisfactory:
   (1) If the test is not satisfactory:
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
5. Close-up
Subtask 38-42-00-710-055-A ** ON A/C NOT FOR ALL
A. Do the test as given in paragraph 3. A. to check the correct operation (no maintenance message is shown).
[Rev.8 from Aug 2018] 2026.04.04 04:34:17 UTC