Unsatisfactory Air Pressure in the Air Supply System
TASK 38-42-00-810-802-A
Unsatisfactory Air Pressure in the Air Supply System
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 38-42-00-710-054-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-42-00-810-053-A ** ON A/C NOT FOR ALL
Subtask 38-42-00-710-055-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:17 UTC
Unsatisfactory Air Pressure in the Air Supply System
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-41-00-820-001 | Adjustment of the Pressure Reducing and Relief Valve |
| AMM 38-41-43-000-001 | Removal of the Pressure Reducing Valve |
| AMM 38-41-43-400-001 | Installation of the Pressure Reducing Valve |
| AMM 38-42-00-710-001 | Operational Test of the Auxiliary Air Supply System. |
| AMM 38-42-00-720-001 | Functional Test of the Pressure Switch |
| AMM 38-42-16-000-001 | Removal of the Pressure Switch |
| AMM 38-42-16-400-001 | Installation of the Pressure Switch |
| AMM 38-42-51-000-001 | Removal of the Compressor |
| AMM 38-42-51-400-001 | Installation of the Compressor |
Subtask 38-42-00-710-054-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-42-00-810-053-A ** ON A/C NOT FOR ALL
A. If the test is not satisfactory:
5. Close-up- do the functional test of the SWITCH,PRESSURE [10MD] AMM 38-42-00-720-001.
- replace the SWITCH,PRESSURE [10MD] AMM 38-42-16-000-001 and AMM 38-42-16-400-001.
- do the adjustment of the pressure and reducing valve AMM 38-41-00-820-001.
- replace the VALVE-PRESSURE REDUCING [4200MM] AMM 38-41-43-000-001 and AMM 38-41-43-400-001.
- replace the COMPRESSOR [8MD] AMM 38-42-51-000-001 and AMM 38-42-51-400-001.
Subtask 38-42-00-710-055-A ** ON A/C NOT FOR ALL
A. Do the test as given in paragraph 3. A. to check the correct operation (no maintenance message is shown).