Potable Water System - Pressure Failure
TASK 38-41-00-810-802-A
Potable Water System - Pressure Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 38-41-00-710-052-A 4. Fault Isolation
Subtask 38-41-00-810-051-A
Subtask 38-41-00-710-053-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:17 UTC
Potable Water System - Pressure Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-41-00-610-001 | Discard System Filter Element |
| AMM 38-41-00-710-001 | Operational Test of the Air Supply System (with ground air supply) |
| AMM 38-41-00-820-001 | Adjustment of the Pressure Reducing and Relief Valve |
| AMM 38-41-43-000-001 | Removal of the Pressure Reducing Valve |
| AMM 38-41-43-400-001 | Installation of the Pressure Reducing Valve |
Subtask 38-41-00-710-052-A 4. Fault Isolation
Subtask 38-41-00-810-051-A
A. If the system pressure is not satisfactory:
5. Close-up- replace the cartridge of the FILTER-AIR [4210MM] , AMM 38-41-00-610-001:
- do the adjustment of the VALVE-PRESSURE REDUCING [4200MM] , AMM 38-41-00-820-001.
- replace the VALVE-PRESSURE REDUCING [4200MM] , AMM 38-41-43-000-001 and AMM 38-41-43-400-001.
Subtask 38-41-00-710-053-A
A. Do the test as given in paragraph 3. A. and make sure that system operates correctly.