Waste Water Drain - Failure
TASK 38-32-00-810-801-A
Waste Water Drain - Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-32-00-710-050-A 4. Fault Isolation
Subtask 38-32-00-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:17 UTC
Waste Water Drain - Failure
1. Possible Causes
- washbasin filter
- drain valve
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-32-00-100-001 | Cleaning of the Waste-Water Drain-Lines |
| AMM 38-32-00-100-002 | Cleaning of the Filter-Element of the Washbasin Drain-Valve Assembly |
| AMM 38-32-00-710-002 | Operational Test of the Waste/Water Drain System |
| AMM 38-32-41-000-001 | Removal of the Drain Valve (Air Stop Valve) |
| AMM 38-32-41-400-001 | Installation of the Drain Valve (Air Stop Valve) |
Subtask 38-32-00-710-050-A 4. Fault Isolation
Subtask 38-32-00-810-050-A
A. If the water drains too slow from the washbasin:
Subtask 38-32-00-710-051-A - Remove and clean the washbasin filter , AMM 38-32-00-100-002.
- Replace the drain valve , AMM 38-32-41-000-001 and AMM 38-32-41-400-001.
- Do the cleaning of the waste water lines AMM 38-32-00-100-001.
B. Do the test as given in paragraph 3. A. and check the correct operation of the waste water drain system.