W DOC AIRBUS | TSM A320F

Waste Water Drain - Failure


TASK 38-32-00-810-801-A
Waste Water Drain - Failure


1. Possible Causes
  • washbasin filter
  • drain valve
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-32-00-100-001
Cleaning of the Waste-Water Drain-Lines
AMM 38-32-00-100-002
Cleaning of the Filter-Element of the Washbasin Drain-Valve Assembly
AMM 38-32-00-710-002
Operational Test of the Waste/Water Drain System
AMM 38-32-41-000-001
Removal of the Drain Valve (Air Stop Valve)
AMM 38-32-41-400-001
Installation of the Drain Valve (Air Stop Valve)
3. Fault Confirmation
Subtask 38-32-00-710-050-A
A. Test
   (1) Do a test of the waste water drain system AMM 38-32-00-710-002.
4. Fault Isolation
Subtask 38-32-00-810-050-A
A. If the water drains too slow from the washbasin:
   (1) If the fault continues:
   (2) If the fault continues:
Subtask 38-32-00-710-051-A
B. Do the test as given in paragraph 3. A. and check the correct operation of the waste water drain system.
[Rev.8 from Aug 2018] 2026.04.04 04:34:17 UTC