W DOC AIRBUS | TSM A320F

Vacuum Pressure of the Vacuum System is Too Low


TASK 38-31-00-810-854-A
Vacuum Pressure of the Vacuum System is Too Low


1. Possible Causes
  • toilet drain lines
  • tank drain line
  • component of the vacuum toilet system
  • GENERATOR,VACUUM [37MG]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-30-00-010-002
Removal of the Toilet Drain Lines
AMM 38-30-00-410-002
Installation of the Toilet Drain Lines
AMM 38-31-00-790-002
Leak Test of the Vacuum Toilet System
AMM 38-31-64-000-001
Removal of the Vacuum Generator
AMM 38-31-64-400-001
Installation of the Vacuum Generator
AMM 38-31-76-000-001
Removal of the Flush Line Check Valves
AMM 38-31-76-400-001
Installation of the Flush Line Check Valves 3322MM/3323MM
3. Fault Confirmation
Subtask 38-31-00-710-154-A
A. Fault Confirmation Test
   (1) Do the leak check of the Vacuum Toilet System AMM 38-31-00-790-002.
4. Fault Isolation
Subtask 38-31-00-810-156-A
A. If the required negative differential pressure (Ref. to the GRAPH 1 and GRAPH 2 in figure 503 of the AMM TASK 38-31-00-790-002) is lower than the measured value:
  • examine the toilet drain lines for leaks with the vacuum system under pressure.
   (1) If you find leaks, repair or replace the defective toilet drain lines AMM 38-30-00-010-002 and AMM 38-30-00-410-002.
   (2) If the fault continues:
   (3) If you have replaced a component of the vacuum toilet system :
  • examine the installed component(s) for the correct installation.
  • make sure that the component(s) does (do) not leak.
   (4) If the fault continues:
Subtask 38-31-00-710-155-A
B. Test
   (1) Do the test given in Para. 3.
   (2) Make sure that the vacuum toilet system operates correctly.
[Rev.8 from Aug 2018] 2026.04.04 04:34:16 UTC