W DOC AIRBUS | TSM A320F

Wrong Message from LLT


TASK 38-31-00-810-853-A
Wrong Message from LLT


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-31-00-710-009
Operational Test of the Toilet Unit
AMM 38-31-00-740-001
BITE Test of the Vacuum Toilet System
AMM 38-31-62-000-001
Removal of the Liquid Level Transmitter
AMM 38-31-62-400-001
Installation of the Liquid Level Transmitter
3. Fault Confirmation
Subtask 38-31-00-710-152-A ** ON A/C NOT FOR ALL
A. Do a test of the vacuum toilet system AMM 38-31-00-710-009.
Subtask 38-31-00-740-084-A ** ON A/C NOT FOR ALL
B. Do the procedure to get access to the CFDS SYSTEM REPORT/TEST menu PAGE AMM 38-31-00-740-001.
4. Fault Isolation
Subtask 38-31-00-810-155-A ** ON A/C NOT FOR ALL
A. If the MCDU gives the maintenance message LIQD LVL XMTR (40MG)
and
the FAP BLUE CARD shows NO WASTE QUANTITY DATA AVAILABLE:
  • fill the waste holding tank with approximately with 5l of water.
   (1) If the messages do no longer show, then the system is ok.
   (2) If the fault continues:
Subtask 38-31-00-710-153-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the test as given in paragraph 3. A. to check the correct operation of the system.
[Rev.8 from Aug 2018] 2026.04.04 04:40:34 UTC