Wrong Message from LLT
TASK 38-31-00-810-853-A
Wrong Message from LLT
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-152-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-084-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-155-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:34 UTC
Wrong Message from LLT
1. Possible Causes
- XMTR-LEVEL [40MG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-62-000-001 | Removal of the Liquid Level Transmitter |
| AMM 38-31-62-400-001 | Installation of the Liquid Level Transmitter |
Subtask 38-31-00-710-152-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-084-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-155-A ** ON A/C NOT FOR ALL
A. If the MCDU gives the maintenance message LIQD LVL XMTR (40MG)
and
the FAP BLUE CARD shows NO WASTE QUANTITY DATA AVAILABLE:
(2) If the fault continues:
Subtask 38-31-00-710-153-A ** ON A/C NOT FOR ALL and
the FAP BLUE CARD shows NO WASTE QUANTITY DATA AVAILABLE:
- fill the waste holding tank with approximately with 5l of water.
(2) If the fault continues:
- replace the XMTR-LEVEL [40MG] , AMM 38-31-62-000-001 and AMM 38-31-62-400-001.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation of the system.
(1) Do the test as given in paragraph 3. A. to check the correct operation of the system.