Toilet System Shuts Down Constantly
TASK 38-31-00-810-851-A
Toilet System Shuts Down Constantly
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-148-A Subtask 38-31-00-740-082-A 4. Fault Isolation
Subtask 38-31-00-810-153-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:16 UTC
Toilet System Shuts Down Constantly
1. Possible Causes
- vacuum leakage
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-00-790-002 | Leak Test of the Vacuum Toilet System |
Subtask 38-31-00-710-148-A Subtask 38-31-00-740-082-A 4. Fault Isolation
Subtask 38-31-00-810-153-A ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report constantly gives the maintenance message LIQD LVL SNSR or LIQD LVL XMTR
and
the FAP constantly gives the maintenance message SYSTEM INOP:
Subtask 38-31-00-810-153-C ** ON A/C NOT FOR ALL and
the FAP constantly gives the maintenance message SYSTEM INOP:
- do the check for vacuum leakage in the vacuum toilet system AMM 38-31-00-790-002.
A. If the LAST/PREVIOUS LEGS Report constantly gives the maintenance message LIQD LVL XMTR (40MG) or LIQD LVL SNSR (41MG)
and
the FAP constantly gives the maintenance messages NO WASTE QUANTITY DATA AVAILABLE and
VACUUM SYSTEM DISABLED - WASTE TANK FULL:
Subtask 38-31-00-710-149-A and
the FAP constantly gives the maintenance messages NO WASTE QUANTITY DATA AVAILABLE and
VACUUM SYSTEM DISABLED - WASTE TANK FULL:
- do the check for vacuum leakage in the vacuum toilet system AMM 38-31-00-790-002.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation of the system.
(1) Do the test as given in paragraph 3. A. to check the correct operation of the system.