W DOC AIRBUS | TSM A320F

28V Failure


TASK 38-31-00-810-845-A
28V Failure


1. Possible Causes
  • AIRCRAFT WIRING
  • DEU-B [300RH8]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
AMM 38-31-00-710-009
Operational Test of the Toilet Unit
AMM 38-31-00-740-001
BITE Test of the Vacuum Toilet System
ASM 383110
3. Fault Confirmation
Subtask 38-31-00-710-137-A ** ON A/C NOT FOR ALL
A. Do a test of the vacuum toilet system AMM 38-31-00-710-009.
Subtask 38-31-00-740-080-A ** ON A/C NOT FOR ALL
B. Do the procedure to get access to the CFDS SYSTEM REPORT/TEST menu PAGE AMM 38-31-00-740-001.
4. Fault Isolation
Subtask 38-31-00-810-147-A ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report gives the maintenance message
LLT (40MG) and LLS (41MG) and VACU GEN (37MG) SPLY
and
the FAP gives the maintenance messages
VACUUM SYSTEM DISABLED ON GROUND
and
NO WASTE QUANTITY DATA AVAILABLE:
   (1) do a check of the AIRCRAFT WIRING for 28VDC at:
  • the liquid level transmitter pin B,
  • the liquid level sensor pin A,
  • the vacuum generator plug B pin A, C
  • the motor start relay pin G, H.
     (a) If there is no 28VDC repair the aircraft wiring as necessary ASM 383110.
   (2) If the fault continues:
Subtask 38-31-00-710-138-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the test as given in paragraph 3. A. to check the correct operation.
   (2) After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:34:15 UTC