Liquid Level Transmitter and Liquid Level Sensor failure
TASK 38-31-00-810-844-A
Liquid Level Transmitter and Liquid Level Sensor failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-135-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-079-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-146-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:15 UTC
Liquid Level Transmitter and Liquid Level Sensor failure
1. Possible Causes
- LLT reference line
- XMTR-LEVEL [40MG]
- SENSOR,LEVEL [41MG]
- DECODER/ENCODER UNIT B [300RH7]
- DEU-B [300RH8]
- filter of the water separator
- water separator
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-47-000-001 | Removal of the Decoder/Encoder Unit B (300RH) |
| AMM 23-73-47-400-001 | Installation of the Decoder/Encoder Unit B (300RH) |
| AMM 38-31-00-100-009 | Cleaning of the Liquid Level Transmitter (LLT) Reference Line |
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-62-000-001 | Removal of the Liquid Level Transmitter |
| AMM 38-31-62-400-001 | Installation of the Liquid Level Transmitter |
| AMM 38-31-63-000-001 | Removal of the Liquid Level Sensor |
| AMM 38-31-63-400-001 | Installation of the Liquid Level Sensor |
| AMM 38-31-67-000-001 | Removal of the Water Separator |
| AMM 38-31-67-400-001 | Installation of the Water Separator |
| AMM 38-31-67-610-001 | Inspect Water Separator and Associated Filter Element, and Clean as Necessary |
Subtask 38-31-00-710-135-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-079-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-146-A ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report gives the maintenance message
LIQD LVL XMTR (40MG) and LIQD LVL SNSR (41MG)
LIQD LVL XMTR OUTPUT VALUE AT FAILURE ENTRY (MILLIAMP),
LIQD LVL SNSR OUTPUT VALUE AT FAILURE ENTRY (VOLT)
and
the FAP give the messages VACUUM SYSTEM DISABLE - WASTE TANK FULL
NO WASTE QUANTITY DATA AVAILABE:
Subtask 38-31-00-710-136-A ** ON A/C NOT FOR ALL LIQD LVL XMTR (40MG) and LIQD LVL SNSR (41MG)
LIQD LVL XMTR OUTPUT VALUE AT FAILURE ENTRY (MILLIAMP),
LIQD LVL SNSR OUTPUT VALUE AT FAILURE ENTRY (VOLT)
and
the FAP give the messages VACUUM SYSTEM DISABLE - WASTE TANK FULL
NO WASTE QUANTITY DATA AVAILABE:
- clean the LLT reference line , AMM 38-31-00-100-009.
- replace the XMTR-LEVEL [40MG] , AMM 38-31-62-000-001 and AMM 38-31-62-400-001.
- Replace the SENSOR,LEVEL [41MG] , AMM 38-31-63-000-001 and AMM 38-31-63-400-001.
- replace the DECODER/ENCODER UNIT B [300RH7] , AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
- replace the DEU-B [300RH8] , AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
- do a check of the overboard vent lines,
- if necessary, clean the overboard vent lines.
- do an inspection of the filter of the water separator ,
- if necessary, clean the filter of the water separator AMM 38-31-67-610-001,
- if necessary, do a check and replacement of the water separator AMM 38-31-67-000-001 and AMM 38-31-67-400-001.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
MCDU Display