LLT / LLS Mismatch
TASK 38-31-00-810-842-A
LLT / LLS Mismatch
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-131-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-144-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:15 UTC
LLT / LLS Mismatch
1. Possible Causes
- LLT reference line
- SENSOR,LEVEL [41MG]
- DECODER/ENCODER UNIT B [300RH7]
- XMTR-LEVEL [40MG]
- DEU-B [300RH8]
- aircraft wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-47-000-001 | Removal of the Decoder/Encoder Unit B (300RH) |
| AMM 23-73-47-400-001 | Installation of the Decoder/Encoder Unit B (300RH) |
| AMM 38-31-00-100-009 | Cleaning of the Liquid Level Transmitter (LLT) Reference Line |
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| ASM 383110 | |
| AMM 38-31-62-000-001 | Removal of the Liquid Level Transmitter |
| AMM 38-31-62-400-001 | Installation of the Liquid Level Transmitter |
| AMM 38-31-63-000-001 | Removal of the Liquid Level Sensor |
| AMM 38-31-63-400-001 | Installation of the Liquid Level Sensor |
Subtask 38-31-00-710-131-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-144-A ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report gives the maintenance message
LIQD LVL XMTR (40MG) / LIQD LVL SNSR (41MG)
LIQD LVL XMTR OUTPUT VALUE AT FAILURE ENTRY (MILLIAMP)
LIQD LVL SNSR OUTPUT VALUE AT FAILURE ENTRY (VOLT):
Subtask 38-31-00-710-132-A ** ON A/C NOT FOR ALL LIQD LVL XMTR (40MG) / LIQD LVL SNSR (41MG)
LIQD LVL XMTR OUTPUT VALUE AT FAILURE ENTRY (MILLIAMP)
LIQD LVL SNSR OUTPUT VALUE AT FAILURE ENTRY (VOLT):
- clean the LLT reference line , AMM 38-31-00-100-009.
- replace the SENSOR,LEVEL [41MG] , AMM 38-31-63-000-001 and AMM 38-31-63-400-001.
- replace the DECODER/ENCODER UNIT B [300RH7] , AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
- replace the XMTR-LEVEL [40MG] , AMM 38-31-62-000-001 and AMM 38-31-62-400-001.
- replace the DEU-B [300RH8] , AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
- do a check and repair the aircraft wiring , ASM 383110.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
MCDU Display