Motor Start Relay Failure
TASK 38-31-00-810-841-A
Motor Start Relay Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-129-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-076-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-143-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:15 UTC
Motor Start Relay Failure
1. Possible Causes
- RELAY [36MG]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-36-000-001 | Removal of the Motor Start Relay |
| AMM 38-31-36-400-001 | Installation of the Motor Start Relay |
Subtask 38-31-00-710-129-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-076-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-143-A ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report gives the maintenance message
MOTOR START RELAY (36MG):
Subtask 38-31-00-710-130-A ** ON A/C NOT FOR ALL MOTOR START RELAY (36MG):
- replace the RELAY [36MG] , AMM 38-31-36-000-001 and AMM 38-31-36-400-001.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
MCDU Display