115 Volt Failure


TASK 38-31-00-810-840-A
115 Volt Failure


1. Possible Causes
  • RELAY [36MG]
  • RELAY-FAN PHASE OFF [38MG]
  • AIRCRAFT WIRING
  • GENERATOR,VACUUM [37MG]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2046500
AMM 38-31-00-710-009
Operational Test of the Toilet Unit
AMM 38-31-00-740-001
BITE Test of the Vacuum Toilet System
ASM 383110
AMM 38-31-36-000-001
Removal of the Motor Start Relay
AMM 38-31-36-400-001
Installation of the Motor Start Relay
AMM 38-31-64-000-001
Removal of the Vacuum Generator
AMM 38-31-64-400-001
Installation of the Vacuum Generator
3. Fault Confirmation
Subtask 38-31-00-710-127-A ** ON A/C NOT FOR ALL
A. Do a test of the vacuum toilet system AMM 38-31-00-710-009.
Subtask 38-31-00-740-075-A ** ON A/C NOT FOR ALL
B. Do the procedure to get access to the CFDS SYSTEM REPORT/TEST menu PAGE AMM 38-31-00-740-001.
4. Fault Isolation
Subtask 38-31-00-810-142-A ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report gives the maintenance message
VACU GEN (37MG) SUPPLY
and
the FAP gives the maintenance message VACUUM SYSTEM DISABLED ON GROUND:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check of the AIRCRAFT WIRING and repair as necessary ASM 383110.
   (3) If the fault continues:
Subtask 38-31-00-710-128-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the test as given in paragraph 3. A. to check the correct operation.
   (2) After the subsequent flight, make sure that the fault does not continue.