Vacuum Toilet Assy Failure
TASK 38-31-00-810-835-A
Vacuum Toilet Assy Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-31-00-710-116-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-070-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-133-D ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:34:15 UTC
Vacuum Toilet Assy Failure
1. Possible Causes
- Flush Valve
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-31-00-710-009 | Operational Test of the Toilet Unit |
| AMM 38-31-00-740-001 | BITE Test of the Vacuum Toilet System |
| AMM 38-31-57-000-001 | Removal of the Flush Valve |
| AMM 38-31-57-400-001 | Installation of the Flush Valve |
| TSM TASK 38-31-00-03 | TOILET SYSTEM - TASK SUPPORTING DATA |
Subtask 38-31-00-710-116-A ** ON A/C NOT FOR ALL Subtask 38-31-00-740-070-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 38-31-00-810-133-D ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report gives the maintenance message
TOILET ASSY LAV X:
20
and the FAP gives the maintenance message
SHUT OFF WATER SUPPLY LAV XX:
Subtask 38-31-00-710-119-A ** ON A/C NOT FOR ALL TOILET ASSY LAV X:
- Look at the error codes on the trouble shooting data page
38-31-00-03 TSM TASK 38-31-00-03 .
20
and the FAP gives the maintenance message
SHUT OFF WATER SUPPLY LAV XX:
- replace the Flush Valve , AMM 38-31-57-000-001 and AMM 38-31-57-400-001.
B. Test
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
(1) Do the test as given in paragraph 3. A. to check the correct operation.
(2) After the subsequent flight, make sure that the fault does not continue.
MCDU Display