W DOC AIRBUS | TSM A320F

Vacuum Toilet Assy Failure


TASK 38-31-00-810-835-A
Vacuum Toilet Assy Failure


1. Possible Causes
  • Flush Valve
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-31-00-710-009
Operational Test of the Toilet Unit
AMM 38-31-00-740-001
BITE Test of the Vacuum Toilet System
AMM 38-31-57-000-001
Removal of the Flush Valve
AMM 38-31-57-400-001
Installation of the Flush Valve
TSM TASK 38-31-00-03
TOILET SYSTEM - TASK SUPPORTING DATA
3. Fault Confirmation
Subtask 38-31-00-710-116-A ** ON A/C NOT FOR ALL
A. Do a test of the vacuum toilet system AMM 38-31-00-710-009.
Subtask 38-31-00-740-070-A ** ON A/C NOT FOR ALL
B. Do the procedure to get access to the CFDS SYSTEM REPORT/TEST menu PAGE AMM 38-31-00-740-001.
4. Fault Isolation
Subtask 38-31-00-810-133-D ** ON A/C NOT FOR ALL
A. If the LAST/PREVIOUS LEGS Report gives the maintenance message
TOILET ASSY LAV X:
   (1) If the last two characters in block 5 of the hexadecimal binary code are:
20
and the FAP gives the maintenance message
SHUT OFF WATER SUPPLY LAV XX:
Subtask 38-31-00-710-119-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the test as given in paragraph 3. A. to check the correct operation.
   (2) After the subsequent flight, make sure that the fault does not continue.
[Rev.8 from Aug 2018] 2026.04.04 04:34:15 UTC