W DOC AIRBUS | TSM A320F

Draining of the Vacuum Toilets is Too Slow


TASK 38-31-00-810-821-A
Draining of the Vacuum Toilets is Too Slow


1. Possible Causes
  • toilet waste lines
  • flow diverter
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-30-00-615-002
Blockage Removal (Orbital Flush Valve)
AMM 38-31-00-100-004
Cleaning of the Toilet Waste Lines with High Pressure Equipment VACLAV 1
AMM 38-31-00-100-005
Cleaning of the Toilet Waste Lines with Crushed Ice
AMM 38-31-00-100-006
Cleaning of the Flow Diverter in the Waste Holding Tank
AMM 38-31-00-100-007
Removal of Blockages at the Inlet Area of the Waste Holding Tank
AMM 38-31-00-710-002
Operational Test of the Vacuum Toilet System
3. Fault Confirmation
Subtask 38-31-00-710-088-A
A. Test
   (1) Do a test of the vacuum toilet system AMM 38-31-00-710-002.
4. Fault Isolation
Subtask 38-31-00-810-101-D
A. If the toilet(s) does (do) not flush normally:
   (1) If the fault continues:
NOTE: The most possible areas for blockage build-up in the waste lines are:
  • at the "Y" duct near the tank,
  • at the tank inlet ducts.
    It is recommended to inspect these areas first.
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
NOTE: It is recommended to clean the waste tank and the waste lines more often to improve the reliability of the system.
Subtask 38-31-00-710-089-A
B. Do the test as given in paragraph 3. A. and check the correct operation of the toilet system.
[Rev.8 from Aug 2018] 2026.04.04 04:34:14 UTC