W DOC AIRBUS | TSM A320F

Rinse Water keeps Flowing in Toilet Bowl


TASK 38-31-00-810-819-A
Rinse Water keeps Flowing in Toilet Bowl


1. Possible Causes
  • RINSE VALVE
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 38-31-00-710-009
Operational Test of the Toilet Unit
AMM 38-31-55-100-001
Remove, clean and inspect Toilet Rinse Valves from all Toilets
3. Fault Confirmation
Subtask 38-31-00-710-085-A
A. Test
   (1) Do a test of the vacuum toilet system AMM 38-31-00-710-009.
4. Fault Isolation
Subtask 38-31-00-810-098-A
A. If water keeps flowing into the toilet bowl after the flush cycle is over:
Subtask 38-31-00-710-086-A
B. Do the test as given in paragraph 3. A. and check the correct operation of the toilet.