Lav X Flush Open Limit Switch Failure


TASK 38-31-00-810-810-A
Lav X Flush Open Limit Switch Failure


1. Possible Causes
  • wiring
  • Limit Switch
  • Flush Valve
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 383114
AMM 38-31-57-000-001
Removal of the Flush Valve
AMM 38-31-57-400-001
Installation of the Flush Valve
3. Fault Isolation
Subtask 38-31-00-810-061-A ** ON A/C NOT FOR ALL
A. If the operational test is not satisfactory:
  • Refer to the bite test last leg or previous legs report page.
    F MCDU Display ** ON A/C NOT FOR ALL
   (1) If the LAST LEG or PREVIOUS LEG gives the maintenance messages LAV X FLUSH V OPEN LIM SW:
  • do a check and repair the wiring between the:
    - FCU connector J3/A / J3/C and limit switch open ASM 383114.
   (2) If the wiring is OK:
  • do a check and adjust the related Limit Switch , refer to the manufacturer's instructions given in the related Component Maintenance Manual (CMM).
   (3) If the fault continues: